NiCo-carbonate pillared bentonite clay-doped carbon paste electrode for sensitive electrochemical detection of phenolic and naphtholic pollutants in wastewater.
Amira Abdullah Wahban, Abdelaziz Elgamouz, Saad Benhaiba, Tanveer Ul Haq, Muhammad Tawalbeh, Abdel-Nasser Kawde
Department of Chemistry, College of Sciences, University of Sharjah, P O. Box: 27272, Sharjah, United Arab Emirates. · Department of Chemistry, College of Sciences, University of Sharjah, P O. Box: 27272, Sharjah, United Arab Emirates. aelgamouz@sharjah.ac.ae.
Key points
From the paper's conclusion- A bentonite clay-doped carbon paste electrode modified with a nickel-cobalt urea composite (NiCoU/BC-CPE) for the detection of phenolic and naphtholic compounds in wastewater was developed.
Abstract
A bentonite clay-doped carbon paste electrode modified with a nickel-cobalt urea composite (NiCoU/BC-CPE) for the detection of phenolic and naphtholic compounds in wastewater was developed. NiCoU/BC was calcined at 300, 500, and 700 °C, with the 700 °C sample exhibiting the best electrochemical performance. At this optimum temperature, FTIR (500-700 cm-1) region and Raman bands near 411 and 563 cm-1 indicated metal-oxygen (M-O) vibrations consistent with the possible formation of spinel-type metal oxide phases. XRD analysis revealed temperature-dependent structural evolution, characterized by the appearance of reflections tentatively associated with spinel-type metal oxides following calcination, along with a diffraction feature near 43.3°, tentatively assigned to the (200) crystallographic plane of NiO in the composite calcined at 700 °C. SEM-EDS showed nanoparticles of 28-85 nm with Ni (6.2 wt%) and Co (1.1 wt%) dispersed on bentonite, and BET analysis revealed a surface area of 29 m2 g-1. The NiCoU/BC@700 °C-modified carbon paste electrode showed optimal phenol response at 5 wt% loading, using SWV in 0.1 M H2SO4 achieving a response of 38.66µA. The sensor exhibited a limit of detection (LOD) of 1.83 µM and a limit of quantification (LOQ) of 6.10 µM, with repeatability and reproducibility relative standard deviation (RSD) values of 0.87% and 3.25%, respectively, indicating good precision in phenol detection. Interference studies demonstrated excellent selectivity in the presence of various organic compounds and metal ions at concentrations ten times higher than phenol. The NiCoU/BC-5wt%-CPE sensing platform was further applied to the determination of gallic acid, 2,4-dichlorophenol, 4-nitrophenol, and 2-naphthol. Gallic acid gave the lowest LOD (1.45 µM), followed by phenol (1.83 µM), 4-nitrophenol (2.09 µM), 2,4-dichlorophenol (2.83 µM), and 2-naphthol (3.99 µM).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrochemical Characterization and Structural Analysis of a Novel Cobalt Phthalocyanine/Histidine-Modified Carbon Paste Biomimetic Composite: Selective Voltammetric Determination of Bisphenol A in Aqueous Media.Biomimetics (Basel, Switzerland) · 2026
- Hybrid CTAB–Silica and APTES-Functionalized Multi-Walled Carbon Nanotubes for Adsorption-Enhanced Electrochemical Detection of Bisphenol A in Environmental and Food SamplesJournal of The Electrochemical Society · 2026
- g-C3N4@Co-BTC nanohybrid-modified electrode for sensitive electrochemical determination of resorcinol in environmental samples.Analytical methods : advancing methods and applications · 2026
- Electrochemical Detection of Methylene Blue Using Ore-Extracted Nb₂ O₅ Nanoparticles Modified Carbon Paste ElectrodeJournal of The Electrochemical Society · 2026
- Development of Binary Pd@PPyC-Bi2O3 Nanocomposite Sensor for Trace-Level Detection of 2,4-Dinitrophenol in Wastewater via Linear Sweep Voltammetry.Chemistry, an Asian journal · 2026
- Bimetallic nanoflower MOF-derived magnetic porous carbon for extraction and quantitative analysis of phthalate esters in environmental water samples.Talanta · 2026