Hemostatic Efficacy and Safety of the Hybrid Injector ClearCoajet in Endoscopic Mucosal Resection of Large Colorectal Polyps: A Multicenter Randomized Trial.
Youngkyeong Nam, Han Hee Lee, Jin Lee, Seung In Seo, Seung Han Kim, Yunho Jung, Dae Young Cheung, Bo-In Lee,
Department of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea. · Department of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea. hanyee99@hanmail.net.
Key points
From the paper's conclusion- In this trial, a ClearCoajet-available strategy was non-inferior to a snare-tip-only strategy, with ClearCoajet effectively controlling most bleeding episodes in that group without additional hemostatic devices. Given the smaller-than-planned sample, this finding should be confirmed in an adequately powered trial.
Abstract
BACKGROUND AND AIMS: We aimed to evaluate the effectiveness and safety of ClearCoajet, a device that combines the hemostatic function of a heat probe with an injector, for hemostasis of intraprocedural bleeding (IPB) during colon endoscopic mucosal resection. METHODS: This multicenter, randomized clinical trial, conducted from October 2022 to April 2025, enrolled patients undergoing EMR for non-pedunculated colorectal polyps measuring ≥ 15 mm. This study evaluated and compared the efficacy and safety of hemostasis for IPB by comparing a snare-tip-only strategy (control group) with a strategy in which hemostasis could be performed using either the snare tip or ClearCoajet at the endoscopist's discretion (Coajet group). RESULTS: A total of 220 lesions were included in the study, with 106 and 114 lesions assigned to the Coajet and control groups, respectively. IPB occurred in 24.1% of EMR procedures, the majority of which were classified as mild cases. Hemostasis was attempted using the assigned interventions for each group. The hemostasis success rate was slightly higher in the Coajet group (96.4% [27/28]) than in the control group (84.0% [21/25]), although the difference was not statistically significant (P = 0.176). The risk difference in hemostasis success was 12.4 percentage points (95% CI, - 4.7 to 31.3). Among the 27 successful cases in the Coajet group, 17 were controlled using ClearCoajet and 10 using the snare tip. No significant differences were observed between the two groups in terms of hemostasis time, post-polypectomy syndrome, or delayed bleeding. CONCLUSIONS: In this trial, a ClearCoajet-available strategy was non-inferior to a snare-tip-only strategy, with ClearCoajet effectively controlling most bleeding episodes in that group without additional hemostatic devices. Given the smaller-than-planned sample, this finding should be confirmed in an adequately powered trial. TRIAL REGISTRATION: www. CLINICALTRIALS: gov NCT05737017.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cold versus hot snare endoscopic mucosal resection for 10-19-mm nonpedunculated colorectal polyps: a multicenter randomized trial.Endoscopy · 2026
- Cold Snare Polypectomy Versus Cold Snare Polypectomy With Submucosal Injection for 3-9 mm Colorectal Polyps: A Randomized Controlled Trial.Journal of gastroenterology and hepatology · 2026
- Cold snare polypectomy versus conventional endoscopic mucosal resection for colorectal polyps 15 mm or smaller: delayed bleeding and resection outcomes in a retrospective cohort.BMC gastroenterology · 2026
- Hybrid endoscopic submucosal dissection-endoscopic mucosal resection of large polyps at the ileocecal valve.VideoGIE : an official video journal of the American Society for Gastrointestinal Endoscopy · 2026
- Targeted In-Defect Clipping After Colonic Endoscopic Resection: A Prospective Feasibility Study.Endoscopy international open · 2026
- Efficacy and Safety of a Novel All In One Device for Colorectal Hybrid ESD: A Multicenter Prospective Study.Clinical and translational gastroenterology · 2026