Clinical & experimental metastasis

THINKERS-X: multisequence MRI radiomics in a mixture-of-experts model for outcome prediction and exploratory dose-scenario evaluation in lung cancer brain metastases treated with radiosurgery.

Jheremy S Reyes, Constantinos G Hadjipanayis, Ajay Niranjan

Department of Neurological Surgery, Center for Image-Guided Neurosurgery, University of Pittsburgh Medical Center, Pittsburgh, PA, USA. · Department of Neurological Surgery, Center for Image-Guided Neurosurgery, University of Pittsburgh Medical Center, Pittsburgh, PA, USA. niraax@upmc.edu.

Observational · n=767

Key points

From the paper's conclusion
  • We developed THINKERS-X: Lung, the eXtended multimodal evolution of THINKERS-Lung, to determine whether multisequence MRI radiomics provides incremental value for lesion-specific outcome prediction and exploratory dose-scenario evaluation after Gamma Knife radiosurgery (GKRS) for lung cancer brain metastases.

Abstract

We developed THINKERS-X: Lung, the eXtended multimodal evolution of THINKERS-Lung, to determine whether multisequence MRI radiomics provides incremental value for lesion-specific outcome prediction and exploratory dose-scenario evaluation after Gamma Knife radiosurgery (GKRS) for lung cancer brain metastases. We performed a retrospective single-center study of 767 patients with 3,728 lung cancer brain metastases treated with GKRS. THINKERS-X preserved the original mixture-of-experts and discrete-time survival architecture while adding a dedicated computational neuroradiology expert. Approximately 2,400 radiomic features per metastasis were extracted from pretreatment FSPGR/T1-weighted postcontrast, T2-weighted, and SWAN MRI. Validation used patient-grouped 5-fold cross-validation and a completely closed patient-grouped internal holdout cohort. In grouped cross-validation, THINKERS-X achieved a mean AUC12 of 0.919 ± 0.021 versus 0.876 for THINKERS-Lung (paired difference, 0.043; 95% CI 0.026-0.061; p < 0.001). In the internal holdout cohort, AUC12 improved from 0.863 to 0.929 (95% CI 0.895-0.958), with a paired difference of 0.066 (95% CI 0.031-0.101; p < 0.001). Mean absolute error decreased from 1.26 to 0.84 months. The calibrated Brier score was 0.039, calibration slope 0.94, and intercept 0.04. Radiomics altered model-derived dose-response profiles in 30.0% of metastases and the model-ranked candidate dose in 23.9%. THINKERS-X improved lesion-specific longitudinal prediction, temporal accuracy, and probabilistic calibration beyond THINKERS-Lung while materially altering exploratory dose-scenario evaluation in a subset of metastases. External multicenter and prospective validation are required before clinical implementation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers