Cell biology and toxicology

Structural lipidomics identifies murine plasma C=C location isomers for radiation dose stratification.

Ruoling Yang, Man Song, Qingyang Liu, Jingwen Tang, Yujun Wei, Dongxue Ge, Kun Qian, Yangliu Shao,

School of Medicine, Nankai University, No. 94 Weijin Road, Nankai District, Tianjin, 300071, China. · Department of Hematology, The First Medical Center of Chinese People's Liberation Army (PLA) General Hospital, Beijing, 100853, China.

Preclinical

Key points

From the paper's conclusion
  • C=C location isomers exhibited favorable dose classification performance in murine plasma. These promising biomarkers provide a foundation for developing translational approaches for acute radiation biodosimetry.

Abstract

BACKGROUND: Rapid and early radiation biodosimetry is essential for post-exposure medical triage and timely intervention. Owing to their high radiosensitivity, lipids are promising biodosimetry biomarkers. However, radiation-induced structural alterations, particularly changes in carbon-carbon double bond (C=C) location isomers, remain poorly characterized. Here, the Paternò-Büchi reaction coupled with liquid chromatography-tandem mass spectrometry (LC-PB-MS/MS) was employed to quantify unsaturated C=C location isomers with minimal interindividual variation. These isomers served as the basis for developing biodosimetry. METHODS: Plasma structural lipidomic profiling was performed in C57BL/6 mice at 4 h and 24 h following irradiation at doses of 0, 2, and 6 Gy using LC-PB-MS/MS. Least absolute shrinkage and selection operator (LASSO) regression was applied to filter dose-dependent lipids for constructing multivariate regression models, validated by receiver operating characteristic analysis curves and bootstrap optimism correction. Mechanistic investigations were conducted using Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway analysis, quantitative real-time polymerase chain reaction, Western blotting, and publicly available transcriptomic databases. RESULTS: Eighty-three species-level lipids and 311 C=C location isomers in phosphatidylcholine and phosphatidylethanolamine were identified in plasma samples. LASSO regression selected 11 isomers at 4 h and 8 lipids at 24 h. Optimized three-feature biodosimetry models demonstrated good performance across both sexes (R2 > 0.8; optimism-corrected area under the curve = 0.8224‒1.0000). Profiling of Δ9 monounsaturated isomer together with KEGG analysis suggested dysregulation of fatty acid desaturation, accompanied by reduced expression of stearoyl-CoA desaturase 1 in AHH-1 cells and murine models. CONCLUSIONS: C=C location isomers exhibited favorable dose classification performance in murine plasma. These promising biomarkers provide a foundation for developing translational approaches for acute radiation biodosimetry.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Structural lipidomics identifies murine plasma C=C location isomers for radiation dose stratification — Science Skim