Influence of thermodisinfection on the mechanical properties of individual human trabeculae from femoral heads.
Katharina Biebl, Alexander Jahnke, Torben Harz, Jacob Siemssen, Sarah Szopko, Kristina Reinfandt, Markus Rickert, Christian Fölsch
Laboratory for Biomechanics, Justus Liebig University Giessen, Giessen, Germany. katharina.biebl@icloud.com. · Laboratory for Biomechanics, Justus Liebig University Giessen, Giessen, Germany.
Key points
From the paper's conclusion- These findings indicate that thermodisinfection largely preserves the intrinsic mechanical properties of individual trabeculae while also influencing failure-related behaviour.
Abstract
Allogeneic bone grafts are frequently used in reconstructive orthopaedics and trauma surgery and require appropriate processing to ensure biological safety. Thermodisinfection represents an established procedure; however, its influence on the mechanical properties of individual trabeculae has not yet been sufficiently investigated. Single trabeculae were prepared from human femoral heads and assigned within a paired study design to either native or thermodisinfected conditions. Mechanical characterisation was performed using a two-point bending test. The elastic modulus (E) was determined from the linear region of the force-displacement curve, and the maximum fracture force ( F max ) was recorded as a measure of load-bearing capacity until structural failure. Furthermore, the influence of anatomical location within the femoral head was analysed. No significant difference in elastic modulus was found between native and thermodisinfected trabeculae. The maximum fracture force was significantly increased in the thermodisinfected group. No consistent differences were observed for either parameter with respect to anatomical location within the femoral head. Thermodisinfection did not significantly impair the elastic properties of individual human trabeculae but significantly affected failure-related behaviour. No consistent influence of anatomical location was observed. These findings indicate that thermodisinfection largely preserves the intrinsic mechanical properties of individual trabeculae while also influencing failure-related behaviour. They complement previous predominantly macroscopic investigations by providing a microstructural perspective on the biomechanical effects of thermodisinfection. Furthermore, the present findings may provide a biomechanical rationale for future bone graft processing strategies involving smaller bone fragments or granule-based graft preparation, although the clinical feasibility of such applications requires further investigation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- From the furnace of Hephaestus: Exploring the influence of heating temperature and diagenetic conditions on thermal modification patterns in porcine bone.Forensic science international · 2026
- Force-thermal behaviors and process optimization of ultrasonic vibration-assisted bone drilling for minimally invasive orthopedic surgeryJournal of Materials Research and Technology · 2026
- A study on the changes in the microstructure of trabecular bone and the biomechanical properties in patients with osteoporotic fractures and the correlation between them.Frontiers in medicine · 2026
- Mechanistic Investigation and Performance Evaluation of Ultrasonic Bone Drilling under Longitudinal-Torsional Coupled Vibration.Medical engineering & physics · 2026
- Material removal mechanism of bone with laser-assisted grinding for low-damage and high-efficiency processMaterials and Manufacturing Processes · 2026
- Intercalary Allograft Reconstruction of the Femur: A Cadaveric Comparison of Intramedullary and Plate Fixation TechniquesJournal of Orthopaedic Research® · 2026