Transmitral flow analysis via valve tracking 4D flow MRI detects age- and sex-related diastolic changes.
Junghwa Choi, Roberto Sarnari, James D Thomas, Michael Markl, Jeesoo Lee
Department of Radiology, Feinberg School of Medicine, Northwestern University, 737 N Michigan Ave. Suite 1600, Chicago, IL, 60611, USA. · Division of Cardiology, Feinberg School of Medicine, Northwestern University, 676 N St. Clair Street, Suite 600, Chicago, IL, 60611, USA.
Key points
From the paper's conclusion- Transmitral flow rates and peak velocities assessed by 4D flow MRI with cine-based valve tracking effectively detected physiologic age-related declines in diastolic function, exhibiting sex-specific differences.
Abstract
To evaluate whether valve tracking 4D flow MRI can detect subtle age- and sex-related changes in left ventricular (LV) diastolic function in healthy adults. We retrospectively recruited healthy adults who had undergone cardiac MRI between October 2020 and March 2022, selecting those with whole-heart 4D flow MRI, 2D long-axis cine, and short-axis cine acquisitions. A dynamic plane at the mitral valve (MV) level was generated in 4D flow MRI using leaflet insertion points tracked on 2- and 4-chamber cine images. Through-plane velocities were computed from 4D flow data and corrected for MV motion. After contouring the transmitral region, early and late diastolic peak flow rates (Eflow, Aflow), peak velocities (Evel, Avel), and mitral forward flow volume (MFVol) were measured. Peak early LV relaxation velocity (EMV) was defined as the peak through-plane velocity of MV plane motion. A total of 39 adults (age range: 46 ± 13; 20 women) were included. With age, both Eflow/Aflow (r = - 0.79, p < 0.0001, adjusted for HR) and Evel/Avel (r = - 0.70, p < 0.0001, adjusted for HR) were significantly decreased, while Evel/EMV increased (r = 0.53, p < 0.001, adjusted for EDV). Early diastolic changes were sex-specific; women showed decreased Eflow and increased Evel/EMV with aging, whereas men showed no significant associations. Additionally, the normalized Eflow/MFVol decreased with aging, significantly in the sex-combined cohort (r = - 0.42, p = 0.008) and in women (r = - 0.68, p = 0.004), but not in men. Transmitral flow rates and peak velocities assessed by 4D flow MRI with cine-based valve tracking effectively detected physiologic age-related declines in diastolic function, exhibiting sex-specific differences.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cardiovascular Magnetic Resonance Reference Values for Left Ventricular Diastolic Function and Left Atrial Sphericity Index in Healthy Adults.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2026
- Automated 4D flow MRI pipeline for the quantification of advanced hemodynamic parameters in the left atriumScientific Reports · 2026
- Impact of Aging, Sex, and Hypertension on Aortoiliac Hemodynamics: A 4-Dimensional Flow Magnetic Resonance Imaging Study.Journal of the American Heart Association · 2026
- Left Ventricular Diastolic Intraventricular Pressure Differences and Propagation Velocity with 4D-Flow MRI in Patients with Hypertrophic CardiomyopathymedRxiv · 2026
- Hemodynamic Flow Signatures: A Novel Paradigm for the Evaluation of Transcatheter Aortic Valve Performance.Circulation. Cardiovascular interventions · 2026
- Quantitative MRI assessment of left ventricular filling: associations with left atrial and pulmonary artery dimensions in a population-based study.Frontiers in cardiovascular medicine · 2026