Key points
From the paper's conclusion- This study compares LA volumes captured from CAC CT and transthoracic two-dimensional echocardiography (2DE).
Abstract
Left atrial (LA) volume is a powerful prognostic factor in cardiovascular disease with emerging AI-driven quantification from non-contrast coronary artery calcium (CAC) CT. The accuracy and agreement of such volume quantification with echocardiography, however, is not well studied. This study compares LA volumes captured from CAC CT and transthoracic two-dimensional echocardiography (2DE). This retrospective cohort included 220 patients undergoing both echocardiography and CAC CT within a 1-year period. CAC CT images were analyzed using a deep learning-based autoencoder model to derive chamber volumes. LA volume measurements were compared using Pearson correlation and Bland-Altman plots. Sub analysis was performed based on CT cardiac phase, body mass index, and sex with LA volume indexed to body-surface area (BSA). Mean LA volume differed significantly between 2DE and CAC CT with volumes of 32.2 ± 13.7 mL/m2 and 45.7 ± 15.9 mL/m2 (P < 0.001), respectively. CAC CT-derived LA volume correlated strongly with 2DE-measured LA volume (r = 0.82, ICC = 0.57, P < 0.001) and substantially with clinical severity (Cohen's κ = 0.70, P < 0.001). 2D-echo systematically underestimated LA volume with CAC-CT, with bias of 13.5 mL/m2 [95% CI, 12.3-14.7]. Agreement remained consistent for patients with (r = 0.83, ICC = 0.66, P < 0.001) and without (r = 0.77, ICC = 0.62, P < 0.001) heart failure. Inter-modality agreement for chamber volumes remained robust across sex, BMI, cardiac phase, and vendor sub-analyses. AI-derived LA volume from CAC CT demonstrated strong correlations with 2DE measurements and severity regardless of cardiac phase, BMI, and sex. Despite systematic differences in absolute volume compared to 2DE, CAC CT revealed relative LA remodeling, supporting the use of CAC CT as a modality for chamber quantification.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI-enabled cardiac chamber volumetry from non-gated chest CT versus echocardiography for prediction of heart failure and atrial fibrillation: an AI-CVD studyEuropean Heart Journal · 2026
- AI-derived LA volume index, LA/RA and LA/LV volume ratios from coronary artery calcium scans predict long-term atrial fibrillation and strokeEuropean Heart Journal · 2026
- Opportunistic Assessment of Coronary Artery Calcium Volume and Density From Non-Electrocardiogram-Gated Chest CT Using Artificial Intelligence: Prognostic Implications in a Screening CohortKorean Journal of Radiology · 2026
- Heart failure and atrial fibrillation prediction from non-gated chest CT scans using AI-based cardiac chamber volumetry an AI-CVD study within the multi-ethnic study of atherosclerosis (MESA)European Heart Journal · 2026
- Heart Failure Outcome Prediction Using Artificial Intelligence-enabled Coronary Artery Calcium CT Chamber Volumetry Compared to American Heart Association PREVENT and the Agatston Score for Heart Failure Risk Stratification.Radiology. Cardiothoracic imaging · 2026
- Fully automatic coronary artery calcium score using CT and artificial intelligence: external validation on a danish populationEuropean Heart Journal · 2026