Diagnostic performance of quantitative flow ratio against intravascular ultrasound in left main coronary artery disease: a prospective single-centre study.
İskan Zengin, Fuat Polat, Deniz Elçik, Erlan Abibulaev, Ramazan Ozan, Rıdvan Yurt, Nihat Kalay, Saban Keleşoğlu,
Department of Cardiology, Kayseri City Hospital, Kayseri, Turkey. · Department of Cardiology, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Educatıon Research Hospıtal, Selimiye Mah. Tıbbiye Cad. No.25 Üsküdar, İstanbul, Turkey. drfuatpolat@gmail.com.
Key points
From the paper's conclusion- These findings limit its utility for LMCA procedural planning and stent optimization, highlighting the need for larger multicenter prospective studies.
Abstract
Accurate assessment of left main coronary artery (LMCA) disease is essential for guiding revascularization. Intravascular ultrasound (IVUS) is the reference standard for anatomical evaluation of intermediate LMCA stenosis, whereas quantitative flow ratio (QFR) is an angiography-derived, wire-free physiological index. Data comparing these modalities in LMCA disease remain limited. This prospective single-center study included 135 patients with LMCA lesions undergoing coronary angiography and IVUS between January 2024 and June 2025. Offline QFR was calculated using QAngio XA 3D. Significant LMCA disease was defined as IVUS-derived minimum lumen area (MLA) < 6 mm² or QFR < 0.80. Agreement, correlation, and diagnostic performance of QFR were evaluated against IVUS. The mean age was 63.4 ± 9.7 years, and 88.1% were male. IVUS identified significant LMCA disease in 92 patients (68.1%) versus 50 (37.0%) by QFR. Agreement was moderate (κ = 0.426, 95% CI 0.197-0.656; p = 0.0003). Using IVUS as the reference, QFR showed 54.3% sensitivity and 100% specificity. QFR correlated moderately with IVUS-derived MLA (r = - 0.416, p < 0.001) but consistently underestimated vessel dimensions (all p < 0.001). On multivariable analysis, QFR < 0.80 (OR 3.52, 95% CI 1.07-11.57; p = 0.039) and distal LMCA bifurcation lesions (OR 2.41, 95% CI 1.03-5.64; p = 0.043) independently predicted IVUS-defined significant disease. QFR demonstrated moderate concordance with IVUS but limited sensitivity, particularly in distal bifurcation lesions, and underestimated vessel dimensions. These findings limit its utility for LMCA procedural planning and stent optimization, highlighting the need for larger multicenter prospective studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Head-to-Head Comparison of Quantitative Flow Ratio, Intravascular Ultrasound, and Coronary Angiography in Left Main Coronary Artery Disease.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Impact of coronary lesion location on the diagnostic performance of Murray law-based quantitative flow ratioEuropean Heart Journal · 2026
- Which diagnostic information is needed to reach expert-level decisions in intermediate left main stenosis? rationale and design of the DECIDE-LM studyFrontiers in Cardiovascular Medicine · 2026
- Repeatability and quality assessment of QFR in the FAVOR III Europe trial: the REPEAT-QFR studyEuroIntervention · 2025
- Diagnostic Accuracy of Artificial Intelligence–Enhanced Ultrasonic Flow Ratio for On-Site Assessment of Coronary StenosisJACC Asia · 2026
- Ultrasonic flow ratio versus Murray law-based quantitative flow ratio for predicting target vessel failure after IVUS-guided PCI.Frontiers in cardiovascular medicine · 2026