A perfusable device for hypoxia studies under continuous flow.
Karim Ameziane, Niyati Kandikanti, Joose Kreutzer, Hannu Välimäki, Meenakshisundaram Kandhavelu, Veikko Sariola, Pasi Kallio
Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland. karim.ameziane@tuni.fi. · Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.
Key points
From the paper's conclusion- Their hypoxic response in the device was confirmed with an intracellular fluorescent hypoxia probe.
Abstract
Due to the central role of oxygen, Organ-on-Chip (OoC) platforms that control oxygen conditions are key to modelling and understanding tissue behaviour, including the development of diseases and their treatment. For example, glioblastoma (GBM) is characterized by extreme intratumoural heterogeneity, including steep oxygen gradients from perivascular regions to necrotic cores. In this study, we introduce a PDMS-based OoC device designed to set and maintain desired oxygen levels within its cell culture region under continuous perfusion. The device can be prepared on a standard microscopy slide and consists of a medium channel surrounded by a gas channel, separated by a PDMS wall enabling gas exchange of the perfused medium. With real-time oxygen imaging, it was determined that hypoxic conditions can be set within the device in 54 min when a flow rate of 4 µL/min is used. The maximum operating flow rate, at which it can maintain the set hypoxia, was determined to be 10 µL/min, providing hypoxic conditions in approximately 34 min. A finite element method (FEM) replica of the device was also developed in silico to predict the behaviour under a large range of conditions. This model estimates that the shear stress in the cell culture region remains under 0.6 mPa at the maximum operating flow rate. Finally, we demonstrate the use of the device by cultivating GBM cells in the device under normoxic and hypoxic conditions. Their hypoxic response in the device was confirmed with an intracellular fluorescent hypoxia probe.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of a Flat-Sheet Membrane Gas Exchange Unit for Oxygen Control in Microfluidic Systems.Micromachines · 2026
- Computational Assessment of Oxygen Availability and Shear Stress in Microfluidic Cell Culture Chambers for Optimized Cell Adhesion.Biosensors · 2026
- Microfluidic Chamber Design for Organ-on-a-Chip: A Computational Fluid Dynamics Study of Pillar Geometry and Pulsatile PerfusionBiosensors · 2026
- An oxygen gradient chamber with simple geometry for generating oxygen gradients in hydrogel-based cell cultures within a well-plate-compatible format.Frontiers in bioengineering and biotechnology · 2026
- Tunable Stiffness of Matrix-Derived Membranes Enables Independent and Coupled Analysis of Pressure and Strain Effects in Barrier Tissue-On-Chip ModelsACS Applied Materials & Interfaces · 2025
- A Simple Liquid Column System for Adjustable Hydrostatic Pressure and Depth-Dependent Hypoxia: Impact on NIH/3T3 Fibroblast Behavior In Vitro.Biology of the cell · 2026