Biomedical microdevices

Multiplexed impedimetric zinc oxide nanorods-modified aptasensor on carbon ink-inscribed paper electrodes for the specific and sensitive co-detection of Alzheimer's and Parkinson's disease.

Saumitra Singh, Anam Ayaz, Osheen Ansari, Humaira Farooqi, Jagriti Narang

Department of Biotechnology, Jamia Hamdard, New Delhi, 110062, India. · Department of Biotechnology, Jamia Hamdard, New Delhi, 110062, India. jags_biotech@yahoo.co.in.

Key points

From the paper's conclusion
  • Overall, this study provides a low-cost, disposable, label-free, and multiplexed proof-of-concept platform for simultaneous AD- and PD-associated biomarker detection.

Abstract

Neurodegenerative diseases, including Alzheimer's disease (AD) and Parkinson's disease (PD), represent a growing health burden, while early diagnosis remains challenging because established diagnostic approaches, including cerebrospinal fluid analysis and neuroimaging, are invasive, expensive, and unsuitable for decentralized point-of-care testing. Recent progress in electrochemical and paper-based biosensors has enabled low-cost, portable, and multiplexed biomarker analysis. However, their clinical translation remains limited by low biomarker concentrations, matrix interference, nonspecific adsorption, sensor-to-sensor variability, storage stability, and the need for validation using clinical samples. Herein, a paper-based multiplex electrochemical aptasensor was developed for simultaneous impedimetric detection of amyloid beta-42 (Aβ-42) and alpha synuclein-60 (αS-60), biomarkers associated with AD and PD, respectively. The device comprised screen-printed carbon and silver electrodes on a cellulose substrate, two independently functionalized working electrodes, zinc oxide nanorods (ZnO-NRs) as electroactive signal-amplification layers, and target-specific DNA aptamers as biorecognition elements. Electrochemical impedance spectroscopy was used for label-free measurement of target-induced changes in charge-transfer resistance. The sensor exhibited a linear response from 0.1 ng/mL to 10 µg/mL for both biomarkers, with limits of detection of 4.41 ng/mL for Aβ-42 and 2.62 ng/mL for αS-60. The platform further detected both analytes in artificial cerebrospinal fluid and artificial saliva, demonstrating that the paper-based sensing interface remains responsive in physiologically mimicked matrices. Overall, this study provides a low-cost, disposable, label-free, and multiplexed proof-of-concept platform for simultaneous AD- and PD-associated biomarker detection. Although the system demonstrates promising performance in artificial matrices, further optimization of sensitivity, surface immobilization, antifouling behaviour, long-term storage, and validation using real clinical saliva and CSF samples will be required before practical diagnostic deployment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Multiplexed impedimetric zinc oxide nanorods-modified aptasensor on carbon ink-inscribed paper electrodes for the specific and sensitive co-detection of Alzheimer's and Parkinson's disease — Science Skim