Biomedical microdevices

A capacitive field-effect sensor utilizing mbene embedded with aptamer-gold nanoparticles for label-free detection of tear TNF-α as a non-invasive diabetic retinopathy biomarker.

Yifan Yao, Lan Deng, Xuyang Wang, Miaomiao Wang, Liuyan Li, Wei Chen, Liping Du, Beenish Noureen,

Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an, 710061, China. · Department of Ophthalmology, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710004, China. aiyi.zhou@xjtu.edu.cn.

Key points

From the paper's conclusion
  • This material was employed, for the first time, to fabricate a capacitive field-effect sensor (CFS), achieving sensitive and rapid detection of TNF-α in tear fluid.

Abstract

Diabetic Retinopathy (DR), recognized as a leading cause of irreversible blindness among adults, poses a severe threat to the visual health of over 500 million individuals with diabetes globally. Recent advancements in non-invasive biomarker detection have offered new avenues for the early diagnosis of DR. Among these biomarkers, tumor necrosis factor-α (TNF-α), a key pro-inflammatory cytokine, is regarded as an optimal biomarker for reflecting DR progression. In this study, we developed a novel composite nanomaterial, AuNPs@CrB, utilizing capacitive field-effect label-free nucleic acid detection technology. This material was employed, for the first time, to fabricate a capacitive field-effect sensor (CFS), achieving sensitive and rapid detection of TNF-α in tear fluid. The biosensor exhibited outstanding analytical performance, achieving a limit of detection (LOD) as low as 2.14 pM and a linear detection range spanning from 0.01 nM to 100 nM. Statistical analysis indicated that the biosensor possesses high specificity toward TNF-α and exhibits favorable detection performance in artificial tear samples, thereby meeting the concentration detection requirements pertinent to clinical diagnostics. Furthermore, the assay features a rapid detection time of less than one minute (with a total assay time of ~ 60 min), which significantly expedites the diagnostic turnaround process. This biosensor holds considerable potential as a novel, non-invasive tool for the early diagnosis of DR and establishes a technical foundation for the detection of additional tear-based biomarkers.

Read the paper