Peak-to-Peak Voltage Mapping Reveals Dynamic Arrhythmogenic Substrate Behavior in Isolated Rabbit Hearts.
José Gomes, Vinicius Silva, Tainan Neves, Jimena Siles, João Salinet
Graduate Program in Biomedical Engineering, Center for Engineering, Modeling and Applied Social Sciences, Federal University of ABC-UFABC, São Bernardo do Campo, SP, Brazil. · HEartLab, Center of Engineering, Modeling and Applied Social Sciences, Federal University of ABC, São Bernardo do Campo, SP, Brazil.
Key points
From the paper's conclusion- These findings establish reference epicardial voltage thresholds for the rabbit heart model and demonstrate the utility of voltage mapping for investigating dynamic arrhythmogenic substrate organization under controlled ex vivo conditions.
Abstract
Cardiac arrhythmias are associated with structural and electrical remodeling processes that generate heterogeneous arrhythmogenic substrates characterized by low-voltage areas and abnormal conduction. Although electroanatomical voltage mapping is widely used for substrate characterization, epicardial voltage thresholds remain highly dependent on species, chamber, and recording configuration, and have not been systematically established for isolated rabbit hearts. We hypothesized that healthy rabbit epicardial tissue exhibits reproducible chamber-specific voltage distributions and that arrhythmias produce dynamic rhythm-dependent low-voltage areas substrate behavior. Isolated New Zealand White rabbit hearts (n = 9) were perfused using a Langendorff system and mapped using custom epicardial multi-electrode arrays. Unipolar EGMs were acquired from the right atrium (RA), left atrium (LA), and ventricular epicardium (V), while bipolar EGMs were derived from adjacent electrodes. Chamber-specific voltage thresholds were determined from sinus rhythm (SR) recordings using 95th percentile criterion. Voltage dynamics were further investigated during induced atrial tachycardia (AT), ventricular tachycardia (VT), and ventricular fibrillation (VF). Unipolar voltage thresholds were 7.4 mV (RA), 8.9 mV (LA), and 17.4 mV (V), whereas bipolar thresholds were 4.1 mV, 5.7 mV, and 9.5 mV, respectively. Arrhythmias significantly reduced peak-to-peak amplitudes compared with SR (p < 0.05), particularly during VT and VF. Longitudinal voltage mapping revealed both transient rhythm-dependent low-voltage areas and spatially persistent low-voltage areas, suggesting distinct functional substrate behaviors during arrhythmogenesis. These findings establish reference epicardial voltage thresholds for the rabbit heart model and demonstrate the utility of voltage mapping for investigating dynamic arrhythmogenic substrate organization under controlled ex vivo conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimal near-field unipolar voltage thresholds using a lattice-tip mapping catheter corresponding to bipolar low-voltage areas in atrial fibrillation ablationEuropean Heart Journal · 2026
- Revisiting low-voltage interpretation: Chamber-specific relationships between myocardial wall thickness and omnipolar voltage.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026
- Cardiac repolarization wave dynamics and its role in arrhythmogenesis.Chaos (Woodbury, N.Y.) · 2026
- Sex-based differences in bi-atrial voltage in atrial fibrillation: a multimodal and digital twin approach to distinguish physiological variation from pathological remodelling.Heart rhythm · 2026
- Spatial heterogeneity of APD under long QT conditions: characterisation and relationship to sinus activation sequence.Cardiovascular research · 2026
- Spatially heterogeneous ionic remodelling promotes wavefront instability in simulated atrial tissue.Frontiers in network physiology · 2026