An Experimental and Computational Investigation to Establish the Mechanical Behaviour of Paediatric Aortic Coarctation Tissue.
Robert D Johnston, Niall Linnane, Shirsha Bose, Damien Kenny, Caitriona Lally
Trinity Centre for Bioengineering, Trinity College Dublin, Dublin 2, Dublin, Ireland. · Royal College of Surgeons, RCSI, Dublin, Ireland.
Key points
From the paper's conclusion- Uniaxial ring testing and histological analysis were used to assess paediatric aortic coarctation samples and to establish fitted material parameters to the experimental data. Quantifying both the combined mechanical response provides preliminary biomechanical data that may be useful for future computational modelling studies investigating aortic coarctation tissue behaviour.
Abstract
PURPOSE: The tissue mechanics resulting in coarctation of the aorta (CoA) remain poorly understood, limiting treatment options, particularly in paediatric patients. Endovascular stenting is the standard of care in adolescents and adults; however current devices are largely used off-label and do not account for the biomechanics or microstructure of the coarcted tissue. This study addresses this knowledge gap by combining uniaxial ring testing, histological assessment and finite element modelling of paediatric aortic coarctation samples to quantify its mechanical behaviour and layer-specific material parameters. METHODS: Aortic coarctation samples were obtained from paediatric patients and analysed using uniaxial ring testing and histology to characterise the tissue's mechanical response and the influence of microstructure. Finite element models were then developed to represent the ductal and aortic layers, and uniaxial ring tests were simulated with material parameters fitted to the experimental data. RESULTS: Uniaxial ring testing of paediatric aortic coarctation samples revealed marked variability in mechanical behaviour. Histological analysis identified two distinct tissue components-ductal and vessel tissue-with qualitative microstructural differences in collagen and elastin, as well as cellular density and morphology. For the first time, material parameters for the individual tissue components were quantified, with first-order Ogden models shown to best capture the experimental and computational behaviour. CONCLUSION: Uniaxial ring testing and histological analysis were used to assess paediatric aortic coarctation samples and to establish fitted material parameters to the experimental data. Quantifying both the combined mechanical response provides preliminary biomechanical data that may be useful for future computational modelling studies investigating aortic coarctation tissue behaviour.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Association between multiaxial mechanical properties and microstructure of porcine descending aorta.Journal of the mechanical behavior of biomedical materials · 2026
- Influence of Fiber Dispersion Representation on the Accuracy of the Mechanical Response of Healthy and Aneurysmal Aortic Wall TissueInternational Journal for Numerical Methods in Biomedical Engineering · 2026
- Regional mechanical and microstructural variations in ascending thoracic aortic aneurysms influenced by tricuspid and bicuspid aortic valvesActa Biomaterialia · 2026
- An Integrated Multiphoton Imaging Workflow for Quantitative Analysis of Aortic Tissue Microstructure.Journal of biomechanical engineering · 2026
- Ex Vivo Micro-Computed Tomography-based Three-Dimensional Modeling and Biomechanical Assessment of the Human Aortic Root.Brazilian journal of cardiovascular surgery · 2026
- Distinct patterns of vascular failure in COL1A1-associated osteogenesis imperfecta and FBN1-associated Marfan syndrome.Frontiers in cardiovascular medicine · 2026