Safety outcomes of half-dose fluorescein and indocyanine green angiography: a clinical assessment of adverse events.
Kouta Kawasaki, Koji Tanaka, Ryusaburo Mori, Hajime Goto, Takumi Kobayashi, Ayaka Nakai, Michiteru Kono, Yu Wakatsuki,
Division of Ophthalmology, Department of Visual Sciences, Nihon University School of Medicine, 1-6 Kandasurugadai, Chiyoda-ku, Tokyo, 101-8309, Japan. · Division of Ophthalmology, Department of Visual Sciences, Nihon University School of Medicine, 1-6 Kandasurugadai, Chiyoda-ku, Tokyo, 101-8309, Japan. Tanaka.koji@nihon-u.ac.jp.
Key points
From the paper's conclusion- Half‑dose dye administration was associated with lower incidences of rash and nausea/vomiting. Dose reduction may contribute to improved safety in FA and ICGA.
Abstract
PURPOSE: To evaluate whether half‑dose administration of fluorescein and indocyanine green is associated with the incidence of adverse events during fluorescein angiography (FA) and indocyanine green angiography (ICGA). STUDY DESIGN: Retrospective cohort study. METHODS: We analyzed 10,435 angiographic examinations in 10,435 unique patients performed using standard doses (fluorescein, 5 mL [500 mg]; indocyanine green, 2 mL [25 mg]) between April 2015 and March 2023, and half doses (fluorescein, 2.5 mL [250 mg]; indocyanine green, 1 mL [12.5 mg]) between April 2023 and March 2024. Explanatory variables included dye dose (half vs. standard), age, sex, diabetes, hypertension, asthma, history of drug allergy, vital signs at examination (systolic/diastolic blood pressure, pulse rate), and meteorological factors (temperature, atmospheric pressure). After univariable analyses, multivariable logistic regression was performed. P < 0.05 was considered statistically significant. RESULTS: Adverse events assessed in the main analyses included rash, nausea/vomiting during FA, ICGA, or combined FA+ICGA, and hypotension. The overall incidence of adverse events was significantly lower in the half‑dose group (6.21%) than in the standard‑dose group (10.65%; P < 0.001). Half-dose administration was associated with lower odds of rash (odds ratio [OR] = 0.46; P = 0.001), nausea/vomiting during FA (OR = 0.24; P < 0.001), and nausea/vomiting during combined FA+ICGA (OR = 0.58; P = 0.002). Younger age was an independent risk factor for several adverse events. CONCLUSIONS: Half‑dose dye administration was associated with lower incidences of rash and nausea/vomiting. Dose reduction may contribute to improved safety in FA and ICGA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Patient's weight-based indocyanine green dose for fluorescence angiography with led imaging system in left-sided colorectal resections.Surgical endoscopy · 2026
- ULTRA-LOW DOSE, SHORT-INTERVAL INDOCYANINE GREEN FOR PEDIATRIC FLUORESCENCE-GUIDED SURGERY: A MULTICENTER EVALUATION.Journal of pediatric surgery · 2026
- Intraoperative biliary anatomy visualization using indocyanine green fluorescence micro-dosing: a quantitative preclinical study.Surgical endoscopy · 2026
- Adverse Events Reported with Standard-Dose and High-Dose Aflibercept: A FAERS Pharmacovigilance StudyVision · 2026
- Assessment of fluorescence interference in the basophil activation test: a case of indocyanine green-induced anaphylaxis.Journal of anesthesia · 2026
- An ultra-low indocyanine green dose maximizes biliary-to-hepatic contrast in dogs: a prospective pilot study.Veterinary journal (London, England : 1997) · 2026