Well-designed k-space coverage is important for good MRI denoising
Jiayang Wang, Justin P. Haldar
University of Southern California
Key points
From the paper's conclusion- This work investigates whether the performance of modern computational denoising methods can be further enhanced by k-space coverage modifications.
Abstract
OBJECTIVE: Modern computational MRI denoising approaches are often designed assuming fixed k-space coverage. This contrasts with earlier acquisition-design literature that leveraged k-space coverage modifications (e.g., reducing spatial resolution) to improve SNR. This work investigates whether the performance of modern computational denoising methods can be further enhanced by k-space coverage modifications. MATERIALS AND METHODS: Using realistic simulations of noisy data, k-space coverage and averaging patterns were optimized for two advanced image denoising/reconstruction approaches: parallel imaging with total variation regularization and a U-Net neural network. For reference, comparisons against classical linear filtering/apodization methods were also performed. Performance was quantified using normalized root-mean-squared error (NRMSE) and structural similarity (SSIM) metrics. RESULTS: Advanced computational denoising methods can be substantially enhanced, both quantitatively and qualitatively, by reducing the spatial resolution of the acquisition to improve SNR. Indeed, even simple linear filtering/apodization with optimized k-space coverage can rival advanced methods using naive higher-resolution coverage. DISCUSSION: Classical acquisition design principles that allow spatial resolution to be traded for SNR enhancement are still very relevant for modern computational denoising techniques. However, the optimization of k-space coverage and denoising/reconstruction methods can also be somewhat confounded because the NRMSE and SSIM metrics have low sensitivity to spatial resolution.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- CoilDrop-MRI: Self-supervised physics-guided MRI reconstruction with coil dropout.Medical image analysis · 2026
- Scan-specific k-space interpolation using deep Koopman autoencodersarXiv · 2026
- SRNR: Deep learning-based MRI super-resolution using noisy high-resolution reference data.Imaging neuroscience (Cambridge, Mass.) · 2026
- Learning Where and How Much to Sample: Volume-Adaptive k-Space Acquisition for Accelerated MRIarXiv · 2026
- Scalable Unrolled Chains for MRI ReconstructionarXiv · 2026
- A Tutorial on MRI Reconstruction: From Modern Methods to Clinical ImplicationsIEEE Transactions on Biomedical Engineering · 2025