Advanced methods in deuterium metabolic imaging
Fabian Niess, Bernhard Strasser, Bernard Lanz, Wolfgang Bogner
Medical University of Vienna · Centre d'Imagerie BioMedicale
Key points
From the paper's conclusion- Abstract Background Deuterium metabolic imaging (DMI) has recently been established as a versatile MR-based technique for in vivo mapping of glucose and other metabolic pathways using safe, non-ionizing 2 H-labeled tracers.
Abstract
Abstract Background Deuterium metabolic imaging (DMI) has recently been established as a versatile MR-based technique for in vivo mapping of glucose and other metabolic pathways using safe, non-ionizing 2 H-labeled tracers. Objective In this review, methodological advances in DMI over the past decade are summarized, spanning hardware, acquisition, reconstruction, and quantification. Approach and Outline Developments in multinuclear system modifications and dual-tuned head and body coils that enable 3D DMI at clinical and ultra-high field strengths are outlined. Efficient spatial–spectral encoding strategies and balanced steady-state-free-precession-based MRSI, which improve SNR efficiency and spatiotemporal resolution, are reviewed together with temporally interleaved 1 H/ 2 H acquisitions that integrate DMI into standard MRI workflows. Indirect 1 H-observed deuterium detection (QELT) is described as a complementary approach for sites without multinuclear hardware. On the reconstruction side, model-based, low-rank and AI-driven methods are highlighted for de-noising, accelerated sampling, and robust spectral–temporal fitting. Outlook Current strategies for concentration estimation, kinetic modeling, and treatment of label loss are discussed, positioning DMI as a promising complement to FDG-PET and 13 C-MRS for studying metabolism in neurological, oncological and systemic disease.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Advancing Deuterium MRI to Track Human Cerebral Glucose Metabolism at 7 T: A Comparison of Glucose‐d₂ and Glucose‐d₇ IngestionNMR in Biomedicine · 2025
- Dynamic deuterium metabolic imaging in glioblastoma at 7TMagnetic Resonance Materials in Physics Biology and Medicine · 2025
- Deuterium Metabolic Imaging‐Based Methods for Assessment of the Hepatocellular Lipid ContentNMR in Biomedicine · 2026
- TMET-20 Validation of Deuterium metabolic imaging-based biomarker of tumor aggressivenessNeuro-Oncology · 2026
- EP03.05 Characterising Metabolic Reprogramming in Glioblastoma Using 7T Deuterium Metabolic ImagingNeuro-Oncology · 2026
- From equilibrium to dynamic metabolic imaging: the evolving role of magnetic resonance spectroscopic imaging in neurodegenerative disorders.Journal of translational medicine · 2026