Assessment of Vestibular Schwannoma Growth After Radiosurgery: Variability in Clinical Decision Thresholds and the Role of Artificial Intelligence.
Ada Chung, Rithvik Ghankot, Ariel Omiunu, Daniel Li, Manwi Singh, Noemi Jester, Kanwar P Singh, Steven M Tommasini,
Yale School of Medicine, New Haven, CT, USA. · Department of Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, CT, USA.
Key points
From the paper's conclusion- AI-human agreement for absolute tumor volumes was comparable to human interobserver agreement. However, longitudinal growth assessment and binary classification demonstrated greater variability, emphasizing the importance of benchmarking AI performance against human variability when applying clinically relevant growth thresholds.
Abstract
PURPOSE: To quantify expert interobserver variability in longitudinal vestibular schwannoma growth assessment after radiosurgery and evaluate AI segmentation performance relative to human variability. MATERIALS AND METHODS: Retrospective review of patients with sporadic unilateral VS treated with stereotactic radiosurgery (2001-2023). Manual and AI segmentations were compared across the cohort. A growth-enriched subset of 24 tumors underwent additional expert assessment. Agreement was evaluated using intraclass correlation coefficients (ICC), Fleiss and Cohen κ, Bland-Altman analysis, and Dice similarity coefficients. RESULTS: The cohort included 170 MRI examinations from 85 patients (45.9% female; median age, 66 years; median follow-up, 53 months). Human interobserver agreement was excellent for baseline volume (ICC, 0.95), follow-up volume (ICC, 0.98), and percent volume change (ICC, 0.89), but decreased for ≥ 20% growth classification (Fleiss κ, 0.52). Eleven of 24 tumors met the strict-majority growth definition. AI-expert agreement was excellent for baseline and follow-up volumes (ICC, 0.99 and 0.97), but lower for percent change (ICC, 0.83). AI achieved 83.5% binary agreement (Cohen κ, 0.47) and median Dice coefficient of 0.85 (IQR, 0.77-0.90). Bland-Altman analysis demonstrated a mean bias of + 6.64 percentage points (95% limits of agreement, - 53.33 to 66.60). CONCLUSIONS: AI-human agreement for absolute tumor volumes was comparable to human interobserver agreement. However, longitudinal growth assessment and binary classification demonstrated greater variability, emphasizing the importance of benchmarking AI performance against human variability when applying clinically relevant growth thresholds.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Volumetric Assessment of Vestibular Schwannomas Exhibiting Internal Growth After Stereotactic Radiosurgery: Application of Artificial Intelligence.Clinical neuroradiology · 2026
- Predicting long-term tumor response to Gamma Knife radiosurgery in vestibular schwannoma: an integrated model of auto-segmentation, MRI radiomics, and dosimetric parameters.Journal of neuro-oncology · 2026
- What Radiomics Teaches Us About Vestibular Schwannoma Biology: Imaging Biomarkers, Artificial Intelligence, and Future Clinical Translation: A Narrative Review.Audiology research · 2026
- Are We Overmonitoring Vestibular Schwannomas? Challenging the Necessity of Tracking Them All.Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2026
- 161 Automated Volumetric Analysis in Neuro-Oncology: Institutional Experience and Clinical Utility of AI-Driven AssessmentNeuro-Oncology Advances · 2026
- Agentic Automation of BT-RADS Scoring Using an End-to-End System for Standardized Glioma Follow-up Assessment.Radiology. Artificial intelligence · 2026