ConvFormer3D: A Hybrid 3D-CNN-Transformer Front-End for Cine cMRI View Classification Pipelines.
Nafiseh Ghaffar Nia, Vinesh Appadurai, Suchithra V, Chinmay Rane, Daniel Pittman, James Carr, Adrienne Kline
Center for Artificial Intelligence, Bluhm Cardiovascular Institute, Northwestern Medicine, Chicago, IL, 60611, USA. · Department of Cardiology, The Prince Charles Hospital, Queensland, Australia.
Key points
From the paper's conclusion- This study presents ConvFormer3D, a hybrid spatiotemporal architecture that includes a Kinetics-400-pretrained 3D residual encoder (R3D-18), modified to handle single-channel cine input, combined with a lightweight temporal transformer and attention-based token pooling.
Abstract
It is vital to reliably identify the views of standard cine cardiac magnetic resonance imaging (cine cMRI), since each determines which cardiac anatomy will be observed and undergo quantitative analysis. If the view is incorrectly identified, whether by a human observer or by an automated system, errors can propagate into subsequent analyses that give rise to the volumetric assessment, strain analysis, evaluation of the valves, and thus diagnostics. Accurate classification remains a challenge due to clinical variation between scanner manufacturers, differences in acquisition protocols, and motion artifacts. This study presents ConvFormer3D, a hybrid spatiotemporal architecture that includes a Kinetics-400-pretrained 3D residual encoder (R3D-18), modified to handle single-channel cine input, combined with a lightweight temporal transformer and attention-based token pooling. The convolutional stages supply local anatomical and motion priors, while the temporal transformer captures time dependencies throughout the cardiac cycle at full temporal resolution. The network is trained using deep auxiliary supervision, label smoothing, an exponential moving average of the parameters, and mixed-precision optimization. The model's predicted probabilities are then calibrated by temperature scaling. To prevent data leakage, the different partitions are created at the level of the individual patient, and all reported metrics are recorded at patient-clustered bootstraps at the 95% confidence interval, together with formal paired significance testing between the various models. On a separate patient-level test partition, ConvFormer3D achieved an accuracy of 0.983 and an expected calibration error of 0.003 after temperature scaling.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- CardioTrace: Motion-Aware Cine Synthesis via Coupled Tracing and SegmentationarXiv · 2026
- Unifying Vision and Language: Benchmarking End to End Transformer Model Against the ClipCap FrameworkmedRxiv · 2026
- A generalizable deep learning system for cardiac MRINature Biomedical Engineering · 2026
- One Frame, Full Heartbeat: ECG-Free 4D Cardiac Cine MRI Synthesis via Radial-Decomposed Flow MatchingarXiv · 2026
- Beyond Training from Scratch: Foundation Models for Data-Efficient and Generalizable Cardiac MRI ReconstructionarXiv · 2026
- Bridging global semantic representation and inference efficiency via hybrid knowledge distillation for clinically deployable cardiac MRI classificationIntelligence-Based Medicine · 2026