Journal of imaging informatics in medicineOpen accessArtificial intelligence

HDFF-Net: A Hybrid Dual-Feature Fusion Network with Bidirectional Gated Fusion for Colposcopic Transformation Zone Classification, Evaluated under a Leakage-Audited Cluster-Level Protocol.

B Shubhaker, B S Raghavendra

Department of Electronics and Communication Engineering, National Institute of Technology Karnataka, Surathkal, Karnataka, 575025, India. shubhaker.subbu@gmail.com. · Department of Electronics and Communication Engineering, National Institute of Technology Karnataka, Surathkal, Karnataka, 575025, India.

Key points

From the paper's conclusion
  • We evaluate HDFF-Net (Hybrid Dual-Feature Fusion Network), a dual-stream design that combines a 10,322-dimensional multi-scale handcrafted feature branch (MS-GLCM, MS-LBP, MS-HOG), projected to 512 dimensions and recalibrated by a 1D Squeeze-and-Excitation (SE) module, with an EfficientNet branch augmented by CBAM.

Abstract

Cervical cancer screening through colposcopy depends critically on accurate classification of the transformation zone (TZ) according to the 2011 IFCPC nomenclature, as TZ type directly governs treatment eligibility (ablative versus excisional). Inter-rater agreement among trained colposcopists for TZ-type assignment is only κ ≈ 0.42-0.60, well below the κ ≥ 0.80 threshold considered reliable for clinical decision-making. Existing automated methods rely either on handcrafted feature pipelines or deep transfer learning in isolation, and published performance figures on public colposcopy atlases have not been systematically audited for evaluation integrity. This paper reports a leakage-audited, cluster-level evaluation of a hybrid handcrafted-plus-deep fusion design on a public colposcopy atlas and asks whether the fusion adds value over simpler baselines when only a few hundred images are available. We evaluate HDFF-Net (Hybrid Dual-Feature Fusion Network), a dual-stream design that combines a 10,322-dimensional multi-scale handcrafted feature branch (MS-GLCM, MS-LBP, MS-HOG), projected to 512 dimensions and recalibrated by a 1D Squeeze-and-Excitation (SE) module, with an EfficientNet branch augmented by CBAM. The two streams are joined by a bidirectional gated fusion (BGF) module that uses feature-wise sigmoid gates; it is not an attention mechanism (no query-key interaction, softmax, attention heads or spatial tokens). Models are trained on a stratified 70/15/15 split made at the level of 194 unique image clusters (seed = 42), obtained by perceptual-hash deduplication (pHash, Hamming distance <= 8) of 366 IARC Cervical Screening Atlas files. Alias files of one cluster are the same physical image, so the primary analysis uses one observation per cluster; all intervals and paired tests are computed at that level and file-level figures are given only as a sensitivity analysis. Ablations compare handcrafted-only, CNN-only, concatenation and gated-fusion variants, and recent CNN and hybrid-feature baselines were retrained on the same locked split. Deduplication reduced 366 files to 194 unique image clusters (120 TZ1/34 TZ2/40 TZ3) after removal of seven label-contradictory clusters. The held-out test partition contains 30 independent clusters (53 files). On these 30 clusters, HDFF-Net (B0) reached accuracy 0.467 (0.283-0.657), balanced accuracy 0.420 (0.204-0.653) and macro-F1 0.407 (0.217-0.585). Ten baselines were compared with it on the same clusters. MobileNetV3-Large had the highest balanced accuracy (0.636 (0.424-0.855)), but no comparator differed significantly from HDFF-Net after Holm correction (smallest adjusted p = 0.386, MobileNetV3; unadjusted exact McNemar p = 0.039), and the intervals overlap broadly: with 30 clusters the study can detect only large differences. HDFF-Net overfitted (training accuracy 100%, validation accuracy 65-71%). In the ablation (five seeds), replacing concatenation by gated fusion changed balanced accuracy by - 0.031 (95% CI - 0.113 to + 0.048; exact p = 1.000), SE gating by + 0.005 (95% CI - 0.044 to + 0.070; exact p = 1.000) and CBAM by + 0.024 (95% CI - 0.049 to + 0.087; exact p = 1.000); the CNN-only variants had higher mean balanced accuracy (0.555 ± 0.065 and 0.579 ± 0.032) than the full fusion model (0.440 ± 0.118). In five-fold cluster-level cross-validation on 194 clusters, all five models tested reached pooled balanced accuracy of only 0.395-0.431 (chance 0.333) with overlapping intervals (Table 10). HDFF-Net is assembled from established components (SE gating, CBAM, an EfficientNet backbone and sigmoid gated fusion). In this study it did not outperform simpler baselines, and neither the gated fusion nor the SE and CBAM modules showed a measurable benefit; it is therefore reported as a negative result, not as an improvement over the state of the art. The contributions supported by the data are: (1) an audit showing that resample-before-split contamination and alias-file leakage in the IARC atlas inflated accuracy from roughly 49-76% to 99%; (2) a cluster-level evaluation protocol with all inference at the level of independent observations; (3) a controlled comparison of handcrafted-only, CNN-only, concatenation and gated-fusion variants, which found no benefit of fusion at this sample size; and (4) documentation of dataset provenance and label uncertainty. With 194 unique images, a single internal split and no external validation, the results support no claim of superiority, generalisability or clinical readiness.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

HDFF-Net: A Hybrid Dual-Feature Fusion Network with Bidirectional Gated Fusion for Colposcopic Transformation Zone Classification, Evaluated under a Leakage-Audited Cluster-Level Protocol — Science Skim