Journal of imaging informatics in medicine

CrossBoneNet: An Ultralightweight Hybrid CNN-ViT Architecture via Asymmetric Reversed Cross-Attention for Radiographic Fracture Detection.

Kamil Akarsu, Orhan Er

Izmir Bakircay University, Izmir, Turkey. 6041002@bakircay.edu.tr. · Izmir Bakircay University, Izmir, Turkey.

Observational

Key points

From the paper's conclusion
  • With a compact footprint (< 3 MB) and high specificity at the default 0.50 operating threshold, CrossBoneNet demonstrates potential as a point-of-care decision support and worklist prioritization tool on resource-constrained devices, while calibrating the decision threshold (e.g., τ = 0.3837 and τ = 0.3449 ) enables high-sensitivity screening modes (achieving 85.03% and 89.96% sensitivity on MUR

Abstract

Misdiagnoses in emergency departments are often associated with the difficulty in interpreting radiological findings on bone fractures due to millimetric fractures, overlapping bones, or superimpositions. Despite the high efficiency of state-of-the-art models in diagnosing such cases, their massive computational requirements severely hinder their implementation on resource-constrained devices in real-world clinical settings. In this study, we propose an ultralightweight CNN-ViT model, CrossBoneNet, which is designed for edge AI compatibility with minimal memory requirements. CrossBoneNet combines local microfracture detection using convolutional neural networks (CNNs) and global anatomical recognition using vision transformers (ViTs). The model merges features from both architectures using the proposed asymmetric reversed cross-attention, where CNN features act as queries and ViT features act as keys and values-to efficiently map fine-grained local anomalies into a broader global anatomical context. Operating with a minimal parameter count (0.593 M) and low computational cost (1.527 GFLOPs), CrossBoneNet achieved a PR-AUC of 0.8498 ± 0.0086 and a ROC-AUC of 0.8427 ± 0.0072 on the MURA dataset in a patient-wise isolated evaluation. It achieves highly competitive performance-remaining within a 4% margin of the 88.59 million parameter ConvNeXt-Base model-while delivering over 99% memory savings. After fine-tuning on the FracAtlas dataset, CrossBoneNet achieved a specificity of 0.9760 ± 0.0080 and PR-AUC of 0.7568 ± 0.0414, demonstrating effective cross-domain transfer learning. With a compact footprint (< 3 MB) and high specificity at the default 0.50 operating threshold, CrossBoneNet demonstrates potential as a point-of-care decision support and worklist prioritization tool on resource-constrained devices, while calibrating the decision threshold (e.g., τ = 0.3837 and τ = 0.3449 ) enables high-sensitivity screening modes (achieving 85.03% and 89.96% sensitivity on MURA, respectively), pending prospective validation. This retrospective study establishes proof of concept; future work will focus on prospective clinical trials and expansion to multiclass fracture classification.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers