Demonstrating the False-Positive Paradox in Radiology with Artificial Intelligence: Estimating Clinically Anticipated PPV, FDR, NPV, and FOR of FDA-Cleared Devices Using Performance Metrics from 510(k) Summaries and Prevalences from Local and Published Data.
Erin Sparnon, Kelvin Stevens, Elizabeth C Song, Robert J Harris, Benjamin W Strong, Michael A Bruno, Woojin Kim, Christoph Wald,
SEI (Systems Evolution, Inc.), Philadelphia, USA. · Faculty of Medicine, University of Freiburg, Freiburg im Breisgau, Germany.
Key points
From the paper's conclusion- This study estimated the positive predictive value (PPV), false discovery rate (FDR), negative predictive value (NPV), and false omission rate (FOR) for recent Food and Drug Administration (FDA)-cleared radiology AI devices by combining publicly reported 510(k) sensitivity and specificity with local or literature-derived prevalence estimates.
Abstract
The false-positive paradox (FPP) describes the counterintuitive phenomenon whereby a test can achieve high sensitivity and specificity yet still produce mostly false-positive results when applied to low-prevalence populations. This phenomenon is particularly relevant to radiology artificial intelligence (AI), where devices are typically marketed and cleared using diagnostic accuracy metrics such as sensitivity, specificity, and area under the receiver operating characteristic curve (ROC-AUC). However, these metrics do not indicate the proportion of false-positive and false-negative outputs clinicians should expect in local practice. This study estimated the positive predictive value (PPV), false discovery rate (FDR), negative predictive value (NPV), and false omission rate (FOR) for recent Food and Drug Administration (FDA)-cleared radiology AI devices by combining publicly reported 510(k) sensitivity and specificity with local or literature-derived prevalence estimates. Public FDA summaries for 38 radiology AI devices authorized in 2024 or 2025 were reviewed, yielding 57 target pathology entries. Median reported sensitivity, specificity, and ROC-AUC exceeded 90%; nevertheless, clinically anticipated FDRs were often high. For example, a large vessel occlusion detector with 90.6% sensitivity and 88.8% specificity was estimated to have a PPV of 29.3% and an FDR of 70.7% at a prevalence of 4.87%, meaning most positive AI alerts would be false positives. These findings do not evaluate device performance but instead illustrate the FPP in radiology AI. Public 510(k) summaries should consistently report sensitivity, specificity, and test set prevalence so that radiologists and other stakeholders can estimate PPV, FDR, NPV, and FOR for their own patient populations before implementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Detection, Diagnostic, and Triage AI Buyer's Guide: Questions that Matter.Journal of imaging informatics in medicine · 2026
- Critical Appraisal of Artificial Intelligence for Rare-Event Recognition: Principles and Pharmacovigilance Case StudiesDrug Safety · 2026
- A 3-Minute Education on the False Positive Paradox Improves Trust Calibration in AI-Assisted Intracranial Aneurysm Detection: A Multinational Randomized Controlled Reader StudymedRxiv · 2026
- Predicting the Value of Radiology Artificial Intelligence Applications: Large-Scale Predeployment Evaluation of a Portfolio of ModelsAmerican Journal of Roentgenology · 2026
- Expert-referenced evaluation of large language models for primary suspect drug identification in the FAERS database.Frontiers in pharmacology · 2026
- Insufficient reporting quality in large language model studies in the field of radiologyInsights into Imaging · 2026