Nondisease Sources of Radiomic Texture Variation on Plain Radiographs: A Cross-Sectional Analysis of Anatomical Region, Projection, and Resolution in a Public Fracture Archive.
Alex Kubiak, Farzard Haji Boloori, Dallon Davis, McCord Meyers, Ianis Ciolacu, Zhuoyan Wu
Department of Surgery, Kansas City University School of Medicine, Kansas City, MO, USA. alex.kubiak@kansascity.edu. · Department of Surgery, Kansas City University School of Medicine, Kansas City, MO, USA.
Key points
From the paper's conclusion- In a public multihospital fracture archive, we quantified how anatomical region and radiographic projection, each adjusted for the other and for image resolution, shift 17 radiomic features, how much feature variance resolution explains, and a bony superimposition contrast defined within region.
Abstract
Radiomic texture features from plain radiographs feed machine learning models on the assumption that they reflect tissue rather than anatomy or acquisition. In a public multihospital fracture archive, we quantified how anatomical region and radiographic projection, each adjusted for the other and for image resolution, shift 17 radiomic features, how much feature variance resolution explains, and a bony superimposition contrast defined within region. This retrospective cross-sectional secondary analysis used FracAtlas (4083 musculoskeletal radiographs from three hospitals); 4024 images were analyzed. For each z-scored feature (10 first-order, 7 Gy-level co-occurrence matrix [GLCM]), linear models estimated adjusted differences (β, SD units), and resolution by variance explained (R2), with Benjamini-Hochberg false discovery rate correction within each factor. Superimposition (hip and shoulder vs hand and leg; n = 3630), a grouping of regions, was analyzed as a pooled regional contrast rather than an independent factor. Region shifted 16 of 17 features (radiomic uniformity, hand vs leg - 0.66 SD [95% CI - 0.72 to - 0.59]). Resolution explained up to 16.8% of single-feature variance and changed the fracture log-odds coefficient by more than 15% for 7 of 10 interpretable features. Projection had the smallest effects (radiomic 10th percentile, lateral vs frontal - 0.32 SD). The superimposition contrast produced the largest shifts (GLCM energy - 2.26 SD [95% CI - 2.36 to - 2.16]). Radiomic texture on plain radiographs varies substantially with anatomy and acquisition, independently of fracture status. Radiograph radiomics studies should record and adjust for region, projection, and resolution, report region-specific estimates, and validate across sites.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Radiomics-based quantitative assessment of the mandibular cortical index on panoramic radiographs.Scientific reports · 2026
- Radiomics in spinal research: a narrative review.Frontiers in bioengineering and biotechnology · 2026
- Impact of noise power spectrum (NPS) peak frequency on CT radiomics features: A computational phantom study.Biomedical physics & engineering express · 2026
- Body Size, Radiation Dose and Exposure Index in Conventional Radiography: A Multicentre Prospective Study.Diagnostics (Basel, Switzerland) · 2026
- Impact of ROI size on fractal dimension values in radiographs using a novel ROI selection method.Journal of stomatology, oral and maxillofacial surgery · 2026
- Radiomic analysis reveals exercise-induced textural changes in the heel fat pad macrochamber layer.Journal of biomechanics · 2026