Journal of imaging informatics in medicine

Optical Spectroscopy and Machine Learning for Skin Cancer Detection: Why Cohort Size, Validation Rigor and Calibration - Not Architecture - Govern Clinical Readiness.

Hoang ChuDuc

VNU University of Engineering and Technology, National University, 144 Xuan Thuy, Cau Giay, Hanoi, Vietnam. hoangcd@vnu.edu.vn.

Observational

Key points

From the paper's conclusion
  • We synthesise 12 attributable optical skin cancer studies and benchmark seven models (four classical, three deep) under identical, fold-isolated preprocessing and patient-level grouped cross-validation on two public NIR cohorts, NIR-SC-UFES (647 spectra, 319 patients) and Deteccthia (152 lesion-level spectra), with discrimination, calibration, repeated and nested cross-validation, decision curve a

Abstract

Optical vibrational spectroscopy - principally Raman, with near-infrared (NIR) reflectance as a lower-cost proxy - combined with machine learning has been proposed as a non-invasive skin cancer triage adjunct, yet the field remains dominated by small single-centre cohorts and by deep networks reported without a matched classical baseline or leakage-free validation. The objective of this study is to determine whether architecture or methodology governs clinical readiness in this data regime. We synthesise 12 attributable optical skin cancer studies and benchmark seven models (four classical, three deep) under identical, fold-isolated preprocessing and patient-level grouped cross-validation on two public NIR cohorts, NIR-SC-UFES (647 spectra, 319 patients) and Deteccthia (152 lesion-level spectra), with discrimination, calibration, repeated and nested cross-validation, decision curve analysis and a three-class extension. Logistic regression reaches an area under the receiver operating characteristic curve (AUC) of 0.774 (95% CI 0.709-0.838) versus 0.663 (0.596-0.727) for the best deep model (1D-CNN); classical models win in 20/20 seeds (Friedman p = 6.2 × 10⁻22) with lower seed-to-seed variance (Levene p = 0.0018). Deep models are significantly worse calibrated (Holm-adjusted p ≤ 0.024) and overfit within a median of 8-21 epochs. Platt scaling halves the expected calibration error (0.077 → 0.038). No model transported to the external cohort (all AUC ≤ 0.56; class signature correlation r =- 0.17). The ordering persists in the three-class task (macro AUC 0.829 versus 0.741). In this small-cohort regime, classical chemometric models match or exceed deep networks and calibrate more readily, and no single-instrument model survives external validation. Gains will come from larger multi-centre cohorts, patient-level leakage-free validation and probability calibration, not from deeper architectures.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers