An On-Premise, Open-Weights Vision-Language Pipeline for Burned-In PHI Removal: Detection, Decision, and Image Degradation on MIDI-B.
Digvijay Patil
University at Buffalo School of Management, Buffalo, NY, USA. dpatil2@buffalo.edu.
Key points
From the paper's conclusion- We asked whether detection or the PHI decision limits removal.
Abstract
Burned-in protected health information (PHI) in DICOM pixel data blocks multi-site imaging research, and better recognition is assumed to be the route to removal. We asked whether detection or the PHI decision limits removal. A layered pixel pipeline built on Florence-2 OCR was evaluated on MIDI-B with the CBIIT validation script. Against the answer key's OCR-independent coordinates, two controlled arms swapped the engine with the decision fixed, then varied the decision over detections. A nine-condition degradation sweep ran to redaction, with Wilson intervals and exact McNemar tests. On clean images, a 0.23 B vision-language model and a CNN OCR at library defaults detected 34/35 and 35/35 regions, flagged the same 10/35 with the decision fixed, and removed the same 33/35. Over fixed detections, Microsoft Presidio flagged 12/35 and a generic rule set 10/35, as 25 of 35 regions are unpatterned markers; redacting every detection reached 35/35, so both shipped misses were decision misses. Under degradation, both engines detected the text in every condition; removal differed most at blur radius 4, 32 versus 26 (p = 0.07), where the CNN OCR misread short markers (exact match 17/25 versus 10/25). An earlier-reported collapse to 18/35 came from a confidence floor in our harness. The strict profile scored 33/35 at 86.7% series accuracy, and the retain profile 32/35 at 97.6%. Removal on clean text is limited by the PHI decision, not the detector. Under synthetic degradation, the engines differ in transcribing short strings, not in detecting them, by a margin this sample cannot resolve. Results are benchmark- and engine-specific.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Semantic de-identification of burned-in PHI in DICOM medical images: a deep learning–NLP pipeline validated on clinical and phantom TMM datasetsFrontiers in Computer Science · 2026
- From Redaction to Restoration: Deep Learning for Medical Image Deidentification and Reconstruction.Journal of imaging informatics in medicine · 2026
- Privacy-preserving techniques in visual computing: applications, challenges, and future directionsFrontiers in Imaging · 2026
- Rethinking Privacy in Medical Imaging AI: From Metadata and Pixel-Level Identification Risks to Federated Learning and Synthetic Data ChallengesRadiology Artificial Intelligence · 2025
- Same Evidence, Different Verdicts: Delivery of CT Images and DICOM Metadata Changes VLM Quality-Control DecisionsarXiv · 2026
- Improving the performance of radiology report de-identification with large-scale training and benchmarking against cloud vendor methods.BMC medical informatics and decision making · 2026