Journal of imaging informatics in medicine

Spatial Validation of General-Purpose Multimodal AI-Generated Target Regions in Peripheral Nerve Block Ultrasound.

Muhammed Emin Zora, Ömer Sert

Department of Anesthesiology and Reanimation, Uşak University Faculty of Medicine, Uşak, Turkey. muhammedeminzora@hotmail.com. · Anesthesiology and Reanimation Clinic, Uşak Training and Research Hospital, Uşak, Turkey.

Observational

Key points

From the paper's conclusion
  • General-purpose multimodal AI produced measurable but limited spatial agreement with expert-defined targets, supporting supervised evaluation or educational use rather than standalone procedural targeting.

Abstract

General-purpose multimodal artificial intelligence (AI) systems can interpret medical images, but their spatial precision for procedural ultrasound has not been well characterized. This prospective image-based agreement study quantitatively evaluated target regions generated by GPT-4.5 on 100 pre-procedural ultrasound images for interscalene, supraclavicular, femoral, and popliteal sciatic nerve blocks. Three experienced anesthesiologists independently delineated target regions, and a consensus region served as the reference standard. Each image was assessed by the AI system in three separate sessions using a standardized prompt. Spatial agreement was evaluated using the Dice similarity coefficient, Jaccard index, centroid distance, and 95th percentile Hausdorff distance; study-specific expert ratings and repeatability were also assessed. For contextual benchmarking, median expert-expert Dice similarity was 0.88 (interquartile range, 0.84-0.89), and median AI-expert Dice similarity was 0.47 (0.38-0.57; p < 0.001 for the paired contextual comparison). The median Jaccard index was 0.31 (0.23-0.40), centroid distance was 6.85 mm (5.85-7.90), and 95th percentile Hausdorff distance was 10.55 mm (8.97-12.22). On the study-specific expert-rating scale, 41% of AI-generated regions received a score of 3 or higher, but only 5% were acceptable without modification. Repeatability was high (median Dice similarity, 0.93), indicating that reproducibility did not imply anatomical accuracy. General-purpose multimodal AI produced measurable but limited spatial agreement with expert-defined targets, supporting supervised evaluation or educational use rather than standalone procedural targeting.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers