Journal of imaging informatics in medicine

OCTA Vessel Segmentation via UNet Transformers and Deformable Receptive Fields: A Motion-Artefact-Resilient Deep Learning Framework.

Mehmood Nawaz, Hing Lam Chang, Muhammad Ameer Hamza, Sheheryar Khan, Khadija Bibi, Muhammad Daud, Ahsan Khan, Hao Wei,

Department of Data Science and Digital Innovation, The Hong Kong Shue Yan University, Hong Kong SAR, China. mehmood.nawaz136@yahoo.com. · Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China.

Computational

Key points

From the paper's conclusion
  • These results show that our framework is reliable, cost-effective, and well suited to clinical use, especially in low- and middle-income settings where multi-scan OCTA hardware may not be available.

Abstract

Optical coherence tomography angiography (OCTA) is a non-invasive medical imaging technique that helps doctors see the blood vessels of the retina and choroid in fine detail. However, OCTA images often suffer from motion artefacts, which lower the accuracy of vessel segmentation in the retina. In this paper, we propose V2Vnet, a robust volume-to-volume deep learning framework that combines a UNet transformer with deformable receptive fields (DRF) to overcome this problem. The transformer encoder captures the overall structure of the input volume and gathers multi-scale information about retinal blood vessels, while the DRF block makes the convolutional sampling grid more flexible by adding learnable two-dimensional offsets to the standard grid. Together, these components allow the network to detect and segment blood vessels accurately in motion-insensitive 3D OCT images from a single scan, removing the need for repeated acquisitions. We trained and evaluated V2Vnet on the public OCTA-500 dataset, and we further tested it on an independent retinal-layer parcellation dataset to check generalisation. Our proposed technique achieved an accuracy of 99.56 % , an mIoU of 69.64 % , an mDice of 79.14 % , and an MSE of 0.0151 on 3D OCTA segmentation, outperforming UNet3D, UNETR, and IPNV2 across all metrics. Even when synthetic motion artefacts were introduced, V2Vnet still delivered the best mIoU and mDice scores. These results show that our framework is reliable, cost-effective, and well suited to clinical use, especially in low- and middle-income settings where multi-scan OCTA hardware may not be available.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

OCTA Vessel Segmentation via UNet Transformers and Deformable Receptive Fields: A Motion-Artefact-Resilient Deep Learning Framework — Science Skim