An Accountable Encounter-Based Imaging Workflow for Point-of-Care Ultrasound: Integrating Image Availability, Clinician Attribution, and Documentation Accountability.
Matthew Riscinti, Nhu-Nguyen Le, Fred Milgrim, Jessica Rast, Allan Bottemiller, Jon Baird, Victor Johnson, Hee Yoon,
Department of Emergency Medicine, Denver Health Medical Center, 777 Bannock Street, Denver, CO, 80204, USA. matthew.riscinti@dhha.org. · Department of Emergency Medicine, Denver Health Medical Center, 777 Bannock Street, Denver, CO, 80204, USA.
Key points
From the paper's conclusion- An accountable EBIW integrating encounter-level acquisition, DICOM routing, immediate image availability, clinician attribution, and documentation accountability was associated with improved capture of ED POCUS utilization.
Abstract
Point-of-care ultrasound (POCUS) is integral to emergency department (ED) care, but traditional order-based imaging workflows (OBIWs) are poorly aligned with unscheduled encounters and dynamic bedside imaging needs. We describe an accountable encounter-based imaging workflow (EBIW) that integrates patient identification, clinician attribution, encounter-linked image routing, and documentation accountability into a unified imaging informatics architecture. We performed a retrospective observational analysis of aggregated ED POCUS charge data from January 2018 through December 2025 at a single urban academic ED. Three sequential workflows were evaluated: a legacy electronic health record (EHR)-based OBIW, a POCUS Manager-based OBIW, and an accountable EBIW. The accountable EBIW links ultrasound images directly to the ED encounter using barcode-based patient and clinician identification and a centralized Digital Imaging and Communications in Medicine (DICOM) router that generates an image availability message. This enables immediate image access in the picture archiving and communication system, EHR, and POCUS management platform before report completion. Charges were not used as a measure of reimbursement or financial return. Because a charge could only be generated after image archival, encounter linkage, documentation, and clinician attestation, charge capture served as a longitudinal system-level marker of completed workflow execution. Charges were normalized by ED visit volume and analyzed using interrupted time series analysis. Transition from the EHR-based OBIW to the POCUS Manager-based OBIW was not associated with an immediate increase in charges. Implementation of the accountable EBIW was associated with an immediate level increase of $11,746 per 1000 visits and a sustained positive quarterly slope thereafter. An accountable EBIW integrating encounter-level acquisition, DICOM routing, immediate image availability, clinician attribution, and documentation accountability was associated with improved capture of ED POCUS utilization.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Utility of Point-of-care Ultrasound in Clinical Care: A Narrative Review.Journal of medical ultrasound · 2026
- Standardizing Resident Point-of-Care Ultrasound Education and Documentation: A Quality Improvement Initiative.JACC. Case reports · 2026
- Machine Learning to Identify Point-of-Care Ultrasound and Evaluate Standardized Documentation: Retrospective Operational Cohort Study.Journal of medical Internet research · 2026
- May the POCUS Be With You! A Call to Radiologists and Sonographers. A Narrative Review.Australasian journal of ultrasound in medicine · 2026
- Barriers and enablers to point-of-care ultrasound use in emergency departments: a multicentre survey of practicing residents in Switzerland.Swiss medical weekly · 2026
- Feasibility and diagnostic accuracy of paramedic-performed prehospital point-of-care ultrasound: a retrospective observational studyScandinavian Journal of Trauma Resuscitation and Emergency Medicine · 2026