Performance, Heterogeneity, and Methodological Quality of YOLO-Based Models for Fracture Detection: A Systematic Review and Meta-Analysis.
Zexi Wang, Yuan Zhang, Yixi Wang, Feng Xue, Yalikun Yusufu, Abulikemu Maimaiti, Yingting Li, Jie Zhang,
Department of Minimally Invasive Spine and Precision Orthopedics, The First Affiliated Hospital of Xinjiang Medical University, Uygur Autonomous Region, Urumqi, 830054, Xinjiang, China. · Xinjiang Medical-Engineering Integration Technology Center, Xinjiang Uygur Autonomous Region, Urumqi, China.
Key points
From the paper's conclusion- This systematic review and meta-analysis aimed to evaluate the technical detection performance of YOLO-based models for fracture detection and examine clinical and methodological factors associated with performance heterogeneity across studies.
Abstract
This systematic review and meta-analysis aimed to evaluate the technical detection performance of YOLO-based models for fracture detection and examine clinical and methodological factors associated with performance heterogeneity across studies. We conducted a PRISMA-compliant systematic review and meta-analysis registered in PROSPERO. PubMed and Web of Science were searched from January 1, 2018, to December 15, 2025, with backward citation tracking. Study quality was assessed using QUADAS-AI. Random-effects meta-analysis with restricted maximum likelihood estimation and Hartung-Knapp-Sidik-Jonkman adjustment was used to pool mAP@0.5. Twenty-nine studies were included. The pooled mAP@0.5 was 0.797 (95% CI 0.725-0.854), with substantial heterogeneity (I2 = 99.2%) and a 95% prediction interval of 0.333-0.969. Population was the only prespecified subgroup factor that remained statistically significant, with lower pooled performance in pediatric than adult cohorts; however, only 7 pediatric studies were available, so this finding was considered preliminary. Anatomical-site differences were non-significant after adjustment, and YOLO version was not significantly associated with performance. A risk-of-bias sensitivity analysis excluding 12 high-risk studies yielded a pooled mAP@0.5 of 0.830 (95% CI 0.745-0.890). An equal-study-weight sensitivity analysis gave a similar estimate (0.823, 95% CI 0.764-0.870). YOLO-based models showed promising overall technical performance for fracture detection, but the literature was highly heterogeneous. The wide prediction interval indicates that performance may vary substantially across settings, and the pediatric subgroup finding remains preliminary. No statistically significant association between YOLO version and performance was detected. At present, these systems seem better suited to focused decision-support roles than to fully autonomous diagnosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Attention-based deep learning in forensic anthropology: Validation of YOLOv12 architecture for automated skeletal fracture detection.Forensic science international · 2026
- Benchmarking Gemini 1.5 Pro in Pediatric Emergency Radiology: Sensitivity Gap and Physiological Bias in the Immature Skeleton.Diagnostics (Basel, Switzerland) · 2026
- Performance of artificial intelligence for fracture detection: an umbrella review and second-order-meta-analysisnpj Digital Medicine · 2026
- Diagnostic accuracy of deep learning models for detecting wrist and distal forearm fractures in pediatric patients: A systematic review and meta-analysis.Emergency radiology · 2026
- Toward End-to-end Artificial Intelligence Systems for Radiographic Fracture Assessment: A Critical Review of Detection, Explainability, and Prognosis.Journal of medical physics · 2026
- Improving pediatric hip fracture detection using deep learning: multicenter validation and clinical reader study.International journal of surgery (London, England) · 2026