Unified Structural Contrastive Learning for LVEF Estimation in Echocardiograms.
Lin Lv, Quanhao Zhu, Xing Han, Zhengxiang Sun, Yuhan Liu, Tianshu Li, Jingjing Xu, Guihua Yao,
School of Integrated Circuits, Shandong University, 1500 Shunhua Road, Jinan, Shandong, 250101, China. · School of Software, Dalian University of Technology, Dalian, Liaoning, China.
Key points
From the paper's conclusion- To address this challenge, we propose a unified structural contrastive learning framework for LVEF applications, designed to seamlessly integrate two complementary structural constraints into the feature learning process through a unifying mathematical formulation.
Abstract
The automatic estimation of left ventricular ejection fraction (LVEF) from echocardiograms is crucial for the diagnosis of cardiovascular diseases. However, constrained by the inherent speckle noise of ultrasound imaging, the complex temporal dynamics of the cardiac cycle, and the continuous distribution characteristics of physiological indicators, current methods often struggle to extract feature representations that exhibit both robustness and semantic continuity. To address this challenge, we propose a unified structural contrastive learning framework for LVEF applications, designed to seamlessly integrate two complementary structural constraints into the feature learning process through a unifying mathematical formulation. The framework dynamically redefines the sampling strategy for positive and negative pairs. Specifically, it incorporates (1) a temporal consistency constraint via key region masking and (2) reconstruction-based denoising during the self-supervised pre-training phase to capture noise-resistant and stable anatomical structures. During the fine-tuning phase, we further introduce an EF-aware continuous constraint to guide the feature space along the LVEF gradient to form an ordered continuous manifold. Extensive experiments on the EchoNet-Dynamic dataset demonstrate that with only 36 input frames, our method achieves a mean absolute error (MAE) of 3.84, a root mean square error (RMSE) of 5.12, and an R2 of 0.82. Furthermore, evaluating its clinical utility using an automated medical report generation pipeline shows that our module improves downstream diagnosis accuracy to 88.21% and enhances report reliability, particularly near critical diagnostic thresholds. Without relying on large-scale external data for pre-training, the proposed method achieves highly competitive performance compared to current state-of-the-art approaches, providing a promising tool for precise cardiac function assessment in clinical settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Weakly supervised anatomical feature learning for cross-dataset ejection fraction estimation from echocardiography videos.BMC medical imaging · 2026
- LDM-Echo: A Latent Diffusion Model for Echocardiographic Image Denoising with Clinical Evaluation.Journal of imaging informatics in medicine · 2026
- Foundation Model Fine-Tuning with Attention-based Multi-View Fusion for Multi-Task Cardiac Function AssessmentarXiv · 2026
- A unified multi-task learning framework for automated assessment of left ventricular structure and its systolic function from echocardiographyScientific Reports · 2025
- Multimodal ECG–language contrastive pretraining enables detection of structural heart disease from 12-Lead ECGEuropean Heart Journal · 2026
- Dual-flow convolutional neural network for automatic measurement of left ventricular ejection fraction and global longitudinal strain in echocardiography.PLOS digital health · 2026