Tomosynthesis and Synthesized-2D Breast AI Outputs in a Biopsy-Referred Cohort: A Diagnostic Study of Agreement and Incremental Decision-Support Value.
Erkan Şahin, Şimal Arslan, Kamil Doğan, Gülden Ballı, Avni Can Karaca, Isabel Raika Durusoy Onmuş, Baha Zengel
Department of Radiology, İzmir University of Economics Medical Point Hospital, İzmir, Türkiye. erkan.sahin@medicalpoint.com.tr. · Department of Radiology, İzmir University of Economics Medical Point Hospital, İzmir, Türkiye.
Key points
From the paper's conclusion- Within this biopsy-referred cohort, the two AI outputs were not interchangeable.
Abstract
To determine whether two malignancy scores co-reported by a deployed breast artificial intelligence (AI) platform, one tomosynthesis-based and one synthesized-image-based, are interchangeable, and whether either adds information beyond clinical-radiological assessment. This single-center retrospective study analyzed 139 breast-level observations (84 malignant, 55 benign) from 134 biopsy-referred women, with histopathology as reference. Agreement between the two scores was assessed by paired comparison, by whether each output marked a lesion, and by threshold classification. A baseline logistic model (age, radiological suspicion, lesion size) was compared with models adding each score. Cancers negative by the tomosynthesis output at the cohort-derived threshold underwent targeted, AI-masked re-review. The outputs differed within individual breasts despite similar overall discrimination (area under the receiver operating characteristic curve [AUC] 0.728 versus 0.717; p = 0.786). Agreement was moderate (kappa = 0.53); among malignant breasts, 21 were flagged by the tomosynthesis output alone versus 6 by the synthesized output (p = 0.006). Adding either score improved model fit (p < 0.001), but discrimination gains were small (AUC 0.809 to 0.841-0.848) and decision-curve improvements uncertain. Of 30 cancers negative by the tomosynthesis output, 25 had no mammographic correlate on re-review, and breast density did not fully explain this pattern. Within this biopsy-referred cohort, the two AI outputs were not interchangeable. This supports treating co-reported outputs as distinct, context-dependent signals and not using a low AI score by itself to downgrade a suspicious finding. The reporting and governance implications require prospective multireader, multicenter validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial Intelligence for Digital Breast Tomosynthesis Screening with and without Prior Examinations in BreastScreen NorwayRadiology Artificial Intelligence · 2026
- AI-based triage and decision support in mammography and digital tomosynthesis for breast cancer screening: a paired, noninferiority trialNature Medicine · 2026
- AI-Based Characterization of Breast Cancer in Mammography and Tomosynthesis: A Review of Radiomics and Deep Learning for Subtyping, Staging, and PrognosisCancers · 2025
- Diagnostic Performance and Concordance of a BI-RADS-Output AI System in Mammography: A Retrospective Study of Radiologists-AI Collaboration.Journal of imaging informatics in medicine · 2026
- Synthetic-to-Clinical Ensemble Learning for Volumetric Breast Tumor Segmentation in Digital Breast Tomosynthesis Under Limited Annotated Data.Diagnostics (Basel, Switzerland) · 2026
- Performance of an Artificial Intelligence Support System on Screening Mammography Cases Proceeding to Stereotactic BiopsyCancers · 2025