AutoDXA, a Custom-Built Dual-Energy X-ray Absorptiometry Reporting Software, Improves Reporting Efficiency and Maintains High Reporting Accuracy.
Achire Nathalia Mbanwi, Madison Wong, Meriam Elias, Alexander Bilbily
Department of Medical Imaging, University of Toronto, Toronto, ON, Canada. · Sunnybrook Health Sciences Centre, Toronto, ON, Canada.
Key points
From the paper's conclusion- AutoDXA could improve the efficiency of DXA reporting, while maintaining high reporting accuracy.
Abstract
Dual-energy x-ray absorptiometry (DXA) technology evaluates bone mineral density and diagnoses osteoporosis. Traditional DXA reporting with manual transcription of numeric data is time consuming and can lead to errors. In this study, we evaluate the efficiency and reporting accuracy of a semi-automated DXA reporting software (AutoDXA). A single institution retrospective analysis from January 2015 to August 2025 was performed. Three methods of DXA reporting, with varying degrees of automation, were compared in terms of report turnaround time. Method 1 (1056 reports) involved only manual transcription of data; Method 2 (1027 reports) involved automated extraction of numeric data for the current study; and Method 3 (615 reports) leveraged the AutoDXA software, which enabled automated extraction of numeric data from the current and previous studies to determine the diagnostic category and 10-year fracture risk. Subgroup analyses evaluating the error rate and comparing the turnaround time when reporting baseline versus comparison studies were also performed. The mean turnaround time with the AutoDXA software (Method 3) was 2.6 × faster than Method 1 [100 vs 261 s, p < 0.0001], and 1.6 × faster than Method 2 [100 vs 155 s, p < 0.0001]. This difference was most evident in the comparison subgroup analysis, where the mean turnaround time with Method 3 was 2.9 × faster than Method 1 [108 vs 317 s, p < 0.0001]. The total error rate with Method 1 was double that with Method 2 [0.8% vs 0.4%]. There were no errors with Method 3. AutoDXA could improve the efficiency of DXA reporting, while maintaining high reporting accuracy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Vendor-Agnostic Multisite Automated Dual-Energy X-Ray Absorptiometry Reporting Using Artificial Intelligence-Based Optical Character Recognition: Impact on Workflow Efficiency and Accuracy.Journal of the American College of Radiology : JACR · 2026
- Updates on the Role of DXA in the Evaluation and Monitoring of OsteoporosisCurrent Rheumatology Reports · 2025
- Standardized framework for periprosthetic DXA in hip and knee arthroplasty: multisociety RAND/UCLA consensus recommendations.Archives of osteoporosis · 2026
- Diagnostic efficacy of a novel bedside dual-energy X-ray absorptiometry device for the diagnosis of osteoporosis: a prospective cohort study.Frontiers in endocrinology · 2026
- Diagnostic Utility of Serial Radiography in Foot Osteomyelitis in People With Diabetes: Influence of Operator Experience on Test Performance.Wound repair and regeneration : official publication of the Wound Healing Society [and] the European Tissue Repair Society · 2026
- Unlocking forensic potential: machine learning-driven estimation of sex, age, and stature from proximal femur using dual-energy X-ray absorptiometry.International journal of legal medicine · 2026