Deep Learning Algorithm-Reconstructed Triple-Rule-Out CT: Image Quality and Performance in Evaluating Coronary Lumen Stenosis.
Yu Du, Xingyan Chen, Jinhua Zhang, Jing Zhang, Yanjie Zhao, Youfa Tang, Suping Chen, Xiangxiang Chen,
Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China. · Computed Tomography Research Center, GE HealthCare, Beijing, China.
Key points
From the paper's conclusion- To assess radiation burden and contrast medium load, image quality, and the performance of AI-reader and junior radiologists in evaluating coronary stenosis using 80-kVp triple-rule-out (TRO) CT with deep learning image reconstruction (DLIR), 159 patients scheduled for TRO were prospectively recruited and randomized into group A (n = 80; 80-kVp with DLIR) or group B (n = 79; 100-kVp with adaptive
Abstract
To assess radiation burden and contrast medium load, image quality, and the performance of AI-reader and junior radiologists in evaluating coronary stenosis using 80-kVp triple-rule-out (TRO) CT with deep learning image reconstruction (DLIR), 159 patients scheduled for TRO were prospectively recruited and randomized into group A (n = 80; 80-kVp with DLIR) or group B (n = 79; 100-kVp with adaptive statistical iterative reconstruction-V [ASIR-V 60%]). Patients were stratified by BMI (< 25 kg/m2 or ≥ 25 kg/m2). Contrast injection rate and volume were tailored to body surface area and tube voltage. Image quality was evaluated for pulmonary, coronary, and thoracic-abdominal arteries, focusing on noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), edge rise slope (ERS), figure-of-merit (FOM), and subjective scoring. The collective diagnosis by two chief radiologists served as the consensus-based reference standard for evaluating AI-reader and junior radiologists' reading consistency on coronary stenosis. Group A showed significantly lower radiation dose (7.29 ± 1.59 mSv vs. 11.22 ± 3.12 mSv, P < 0.001) and contrast volume (51 ± 5 mL vs. 62 ± 7 mL, P < 0.001) compared to group B. Group A also demonstrated lower image noise, higher SNR and CNR, comparable or superior ERS, and higher FOM across nine artery sites. Subjective scores for sharpness, vascular contrast, small-branch visibility, and overall image quality were comparable or better in Group A. AI-reader and junior radiologists performed similarly in classifying coronary stenosis in both groups. Then, 80-kVp TRO-CT with DLIR reduced radiation by 35.1% and contrast by 18.8%, while maintaining excellent image quality and diagnostic performance across BMI groups, offering a superior dose-to-quality balance compared to conventional methods.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High-Strength Deep Learning Image Reconstruction Versus Adaptive Statistical Iterative Reconstruction for Stenosis Assessment in Stented Coronary Vessels on Coronary CT Angiography: A Multireader Study.Journal of clinical medicine · 2026
- Feasibility of deep learning reconstruction algorithm combined with the "ultra triple-low" protocol at 60 kVp in CTPA: An image quality and radiation dose assessment.European journal of radiology · 2026
- Cardiac-Specific AI Reconstruction Versus Hybrid Iterative Reconstruction for Emergency Coronary CT Angiography: A Paired Single-Center Study Including Triple-Rule-Out CT.Journal of clinical medicine · 2026
- Application value of combining low tube voltage and deep learning image reconstruction algorithm in head and neck CT angiography with reduced radiation and contrast doses.European journal of radiology · 2026
- Deep Learning-Based Automated Coronary Plaque Quantification with Ultra-high Resolution Photon-Counting Detector CT at Different Spatial ResolutionsAcademic Radiology · 2026
- Deep learning denoising and deep learning-augmented contrast enhancement improve ultra-high-resolution photon-counting-detector CCTA image quality.European radiology experimental · 2026