A Grok API-Based DICOM File-Attachment Structured Reporting Workflow for Silicone Breast Implant MRI: a Single-Center Proof-of-Concept Agreement Study.
Diba Saygılı Öz, Mert Efe Sevim, Özge Tanişman, Ömer Faruk Öz, Sacide Efsun Ürger
Department of Radiology, Antalya City Hospital, Antalya, Turkey. 202550052001@ogr.akdeniz.edu.tr. · Department of Biostatistics and Medical Informatics, Faculty of Medicine, Akdeniz University, Antalya, Turkey.
Key points
From the paper's conclusion- The workflow achieved 88.9% binary accuracy, but provider-side DICOM pixel decoding and Pixel Data access were unverified, and metadata-mediated inference cannot be excluded.
Abstract
This study aims to evaluate a Grok application programming interface (API)-based file-attachment structured reporting workflow for silicone breast implant rupture detection on magnetic resonance imaging (MRI), using radiologist consensus as the reference standard. This retrospective single-center study included 95 patients with 180 evaluable implants. Anonymized native Digital Imaging and Communications in Medicine (DICOM) instances were submitted through a custom interface using a fixed prompt and attached to the Responses API as input_file objects without application-side rendering. Provider-side DICOM pixel decoding could not be independently verified; metadata-mediated inference could not be excluded. The workflow generated human-readable reports and machine-readable outputs. The primary endpoint was binary rupture detection; secondary endpoints were agreement and three-class performance. Radiologist consensus classified 156 implants as intact and 24 as rupture-positive, including 20 intracapsular and 4 extracapsular ruptures. The workflow produced 141 true-negative, 19 true-positive, 15 false-positive, and 5 false-negative classifications. Sensitivity was 79.2% (95% confidence interval [CI], 57.8-92.9%), specificity was 90.4% (95% CI, 84.6-94.5%), accuracy was 88.9% (95% CI, 83.4-93.1%), positive predictive value was 55.9%, and negative predictive value was 96.6%. Binary agreement was 88.9%, with Cohen's kappa of 0.591 and Gwet's agreement coefficient 1 of 0.848. All four extracapsular ruptures were classified as intracapsular rupture. The workflow achieved 88.9% binary accuracy, but provider-side DICOM pixel decoding and Pixel Data access were unverified, and metadata-mediated inference cannot be excluded. Accordingly, the results reflect workflow-level performance rather than validated pixel-level interpretation and support only supervised reporting or educational use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic performance of chat generative pre-trained transformer in detecting silicone implant rupture on breast magnetic resonance imaging.Journal of clinical imaging science · 2026
- From a Clinical Mammography Archive to an AI-Ready Imaging Cohort: A Single-Center Implementation and Evidence Audit.Journal of imaging informatics in medicine · 2026
- Feasibility of Auditing Preoperative Breast MRI for Extent-of-Disease Evaluation Using the BI-RADS v2025 ManualRadiology · 2025
- ImageBR: A Public MRI Dataset for Planned Implant Region and Mammary Gland Segmentation in Breast Reconstruction.Journal of imaging · 2026
- Implementation of a Locally Deployed Qwen2.5-7B-Instruct Pipeline for Structured Classification of Elbow MRI Reports.Cureus · 2026
- MicroRAG : Development of a Novel Artificial Intelligence Retrieval‐Augmented Generation Model for Microsurgery Clinical Decision SupportMicrosurgery · 2025