pix2pixHDv2: Efficient Panoramic Dental Image Synthesis with Minimal Artifacts and Computational Overhead.
Merter Hami Karacan, Sait Can Yucebas
Department of Computer Engineering, Canakkale Onsekiz Mart University, Canakkale, 17020, Turkey. merterhk@gmail.com. · Department of Software Engineering, Canakkale Onsekiz Mart University, Canakkale, 17020, Turkey.
Key points
From the paper's conclusion- These findings demonstrate that targeted architectural refinements can substantially improve both image fidelity and resilience against artifacts in dental imaging applications.
Abstract
Although recent image-generation studies have achieved promising results, they still present challenges in terms of computational cost and training/inference time that need to be addressed. Conditional generative adversarial networks (mask-to-image) such as pix2pixHD can synthesize high-resolution panoramic dental radiographs, yet they often introduce underreported artifacts (e.g., circular blotches and checkerboard patterns). This study characterizes these artifacts and proposes pix2pixHDv2, a lightweight architecture that replaces ResNet residual blocks with ConvNeXt and ConvNeXtV2 modules and substitutes transposed-convolution upsampling with bilinear upsampling or PixelShuffle. Using five public datasets (OdontoAI, TUFTS, ADLD, TSXK, AKUDENTAL), models were trained under matched hyperparameters and evaluated for distributional similarity and perceptual quality. Gradient-weighted Class Activation Mapping (Grad-CAM) shows that the proposed residual design shifts early attention toward anatomically relevant tooth regions and suppresses spot-like artifacts, while frequency-spectrum analysis indicates reduced checkerboard periodicity. These findings demonstrate that targeted architectural refinements can substantially improve both image fidelity and resilience against artifacts in dental imaging applications. The ConvNeXtV2 + ConvTranspose2d configuration achieved improvements of 16.3%, 36.5%, 2.8%, and 5.1% in FID, KID, LPIPS, and DISTS, respectively. In addition, synthetic images generated using different backbone and upsampling configurations were presented to 16 specialists in oral and maxillofacial radiology, and an AUROC of 0.65 indicated that distinguishing synthetic images from real radiographs was challenging for expert observers. The addition of synthetic images was associated with a 5.2% relative increase in segmentation performance. Code is available at: https://github.com/merterhk/pix2pixHDv2.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI-Generated Synthetic Panoramic Radiograph for Enhanced Dental Image AnalysisJournal of Imaging Informatics in Medicine · 2026
- A Two-Stage Crack Image and Mask Generation Network for Data Augmentation Toward Efficient Crack DetectionSymmetry · 2026
- Developing Synthetic Orthopantomogram Datasets Through Generative ModelsInternational Dental Journal · 2026
- CarDiff: Anatomically Aware Dental Caries Synthesis using DiffusionarXiv · 2026
- Intentional Degradation for Stabilizing Residual Learning in Coarse-to-Fine Medical Image Refinement.Journal of imaging · 2026
- VISION-GAN: Mask Conditioned U-Net GAN with Multi-Scale Auxiliary Supervision for Retinal Fundus Image Generation.Journal of imaging informatics in medicine · 2026