DINOv2-Pretrained Vision Transformers for Stroke and Heart Failure Detection from Chest X-rays with Limited Labeled Data.
Ming-Han Tsai, Jalu Veda, Jenq-Shiou Leu, Chia-Ti Tsai
Department of Electronic and Computer Engineering, National Taiwan University of Science and Technology, Taipei, 106, Taiwan (R.O.C.). · Department of Electronic and Computer Engineering, National Taiwan University of Science and Technology, Taipei, 106, Taiwan (R.O.C.). jsleu@mail.ntust.edu.tw.
Key points
From the paper's conclusion- We propose a three-stage framework that combines DINOv2 self-supervised learning with vision transformers (ViTs) to detect stroke and heart failure from CXRs under limited labeled data.
Abstract
Cardiovascular and cerebrovascular diseases are leading causes of death worldwide, motivating scalable, noninvasive screening approaches. Chest X-rays (CXRs) are widely available, but current deep learning methods rely on large labeled datasets that are costly to obtain in clinical practice. We propose a three-stage framework that combines DINOv2 self-supervised learning with vision transformers (ViTs) to detect stroke and heart failure from CXRs under limited labeled data. A ViT-Small/14 backbone is first initialized with DINOv2 weights pretrained on LVD-142M dataset and then further adapted by self-supervised pretraining on 5368 unlabeled CXRs from the UCSD dataset, with the bottom 8 transformer blocks frozen to preserve general visual representations during domain adaptation. Model evaluation is performed via frozen-backbone linear probing on 2000 labeled images per task from the NTUH-iMD database. Ablation experiments confirm that each pretraining stage contributes measurable gains under linear probing. Benchmarked against five SSL baselines spanning general domain and medical domain pretraining under an identical evaluation protocol, our stroke model achieves 89.60 ± 1.39% accuracy and 89.55 ± 1.40% F1-score, outperforming all baselines including RAD-DINO, which uses nearly four times the parameters. Our heart failure model achieves 92.52 ± 1.57% accuracy, surpassing GLoRIA, CheXzero, and RAD-DINO. We further show that negative class composition critically affects performance and that normal CXR proportion should be interpreted in light of its effect on task difficulty. Attention visualizations confirm that both models focus on anatomically meaningful cardiac and pulmonary regions, supporting the clinical interpretability of the proposed framework.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Resolution-dependent self-supervised transfer in chest radiograph classification.Communications medicine · 2026
- Vascular Anatomy-aware Self-supervised Pre-training for X-ray Angiogram Analysis.IEEE transactions on bio-medical engineering · 2026
- Advancing human-centric AI for robust X-ray analysis through holistic self-supervised learning.Nature communications · 2026
- Towards Whole-Study Screening for Congenital Heart Disease in Fetal Ultrasound Using Multiple Instance LearningarXiv · 2026
- Comparative Study of CNN, Hybrid, and Transformer Architectures in Medical Image Classification.Journal of imaging informatics in medicine · 2026
- Multi-OCT-SelfNet: integrating self-supervised learning with multi-source data fusion for enhanced multi-class retinal disease classificationFrontiers in Systems Biology · 2026