Dental implant geometries enhancing the efficacy of hydrophilic-surface treatments: a retrospective cohort study.
Akinori Moroi, Karen Gomi, Young-Min Shin, Reiji Kojima, Riku Kohara, Kunio Yoshizawa, Koichiro Ueki
Department of Oral and Maxillofacial Surgery, Division of Clinical Medicine, Interdisciplinary Graduate School, University of Yamanashi, 1110 Shimokato, Chuo, 409-3898, Yamanashi, Japan. amoroi@yamanashi.ac.jp. · Department of Oral and Maxillofacial Surgery, Division of Clinical Medicine, Interdisciplinary Graduate School, University of Yamanashi, 1110 Shimokato, Chuo, 409-3898, Yamanashi, Japan.
Key points
From the paper's conclusion- These findings suggest that temporal changes in implant stability differ among combinations of implant geometry and surface characteristics.
Abstract
The influence of implant geometry on the clinical performance of hydrophilic surfaces remains unclear. This retrospective cohort study evaluated longitudinal changes in implant stability according to implant geometry and surface characteristics. Initially, 48 Japanese patients received 88 implants in the posterior region, equally distributed among four groups: hydrophilic-tapered, hydrophilic-cylindrical, hydrophobic-tapered, and hydrophobic-cylindrical. One hydrophilic-tapered implant failed approximately one month after placement and was excluded from the analyses, leaving 47 patients and 87 implants for the final analysis. Implant stability quotient (ISQ) values were assessed immediately after placement and at one and three months postoperatively. Repeated measurements were analyzed using generalized estimating equations with patient-level clustering, adjusted for implant diameter category, length, and position, followed by Bonferroni-adjusted pairwise comparisons of estimated marginal means. A significant group-by-time interaction was observed (Wald χ² = 18.875, p = 0.004). At placement, the hydrophilic-tapered group exhibited significantly higher ISQ values than the hydrophilic-cylindrical (p = 0.001) and hydrophobic-tapered groups (p = 0.019). No significant between-group differences were observed at one month. At three months, the hydrophobic-tapered group showed significantly lower ISQ values than the hydrophilic-cylindrical (p = 0.012) and hydrophobic-cylindrical groups (p = 0.024). All four groups demonstrated significant increases in ISQ values from placement to three months, whereas only the hydrophilic-cylindrical group showed a significant increase during the first postoperative month (mean increase = 5.998, p < 0.001). These findings suggest that temporal changes in implant stability differ among combinations of implant geometry and surface characteristics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hydrophilic versus hydrophobic implant coatings: A comparative osseointegration study.Bioinformation · 2026
- Peri-implant hard-tissue response to hydrophilic implant surfaces in animal models: A systematic review and meta-analysis.Journal of prosthodontic research · 2026
- Comparative Assessment of Primary Stability, Secondary Stability, and Marginal Bone Loss in Immediate Post-Extraction Implants: A Retrospective Study of Three Implant Macro-Geometries.Dentistry journal · 2026
- Do hydrophilic implant surfaces provide a clinically meaningful advantage?Evidence-based dentistry · 2026
- Clinical evaluation of early implant stability using resonance frequency analysis: a multicenter observational study.Frontiers in dental medicine · 2026