Predicting the final color of layered resin composites from background-dependent optical measurements: a translucency-informed model.
Mehmet Buldur, Bengü Doğu Kaya, Berkant Sezer
Faculty of Dentistry, Department of Restorative Dentistry, Çanakkale Onsekiz Mart University, Çanakkale, Türkiye, Turkey. dtmehmetbuldur@gmail.com. · Faculty of Dentistry, Department of Restorative Dentistry, Çanakkale Onsekiz Mart University, Çanakkale, Türkiye, Turkey.
Key points
From the paper's conclusion- Therefore, this study investigated whether background-dependent optical measurements and translucency parameters could be used to predict final color coordinates and assessed model performance in an independent composite system.
Abstract
The final color of layered resin composite restorations is influenced by complex optical interactions between composite layers and surrounding backgrounds. Therefore, this study investigated whether background-dependent optical measurements and translucency parameters could be used to predict final color coordinates and assessed model performance in an independent composite system. During model development, five composite shades (D3, D2, D1, E2, and E1) were used in both the 2-mm base and 1-mm top positions, generating all 25 possible ordered bilayer combinations. Background-dependent L*, a*, and b* coordinates and translucency parameters obtained from independent 1-mm and 2-mm layers were used to develop multivariable linear regression models for predicting the color coordinates of 3-mm layered specimens. Model performance was assessed using adjusted R², mean absolute error, root mean square error, and leave-one-out cross-validation. Independent-system evaluation was performed using 16 layered combinations from one additional composite system, and predictive accuracy was evaluated using CIEDE2000 color differences (ΔE00). The regression models demonstrated adjusted R² values of 0.799, 0.843, and 0.964 for the L*, a*, and b* coordinates, respectively. During the independent-system evaluation, the mean ΔE00 value was 0.939 ± 0.333; 37.5% of the combinations were at or below the perceptibility threshold (ΔE00 ≤ 0.8), while all combinations (100%) were within the clinical acceptability threshold (ΔE00 ≤ 1.8). Background-dependent optical measurements and translucency parameters enabled accurate and clinically acceptable estimation of the final color coordinates of layered resin composites. The low prediction errors observed in one additional composite system provide preliminary evidence of predictive performance beyond the development material under standardized experimental conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multidimensional instrumental and visual evaluation of metamerism in single-shade resin composites: effects of color-matching technology, underlying color, thickness, and translucency.Odontology · 2026
- Refractive Index and Translucency of Contemporary Esthetic Resin Composites Relative to Human Enamel: An In Vitro Study.Journal of functional biomaterials · 2026
- Optical Stability of Injectable Resin Composites with Different Shade-Matching Strategies.Polymers · 2026
- Color Change and Color Match of Universal-Shade Resin Composites over Discolored Tooth Structure: Effect of Thickness and an Opaque Blocker—An Exploratory In Vitro StudyDentistry Journal · 2026
- Optical properties and staining susceptibility of single-shade composite resins and their conventional counterparts.General dentistry · 2026
- Color and Relative Translucency of Three-Dimensionally Printed Restorative Resin Systems: Effects of Build Orientation, Thickness and Staining Conditions.Polymers · 2026