Biomechanics and modeling in mechanobiology

In Vivo cardiac biomechanical model parameter estimation from ultrafast shear wave elastography.

Camilla Ferrario, Maëlys Venet, Olivier Villemain, Maxime Sermesant

Inria, Sophia Antipolis, France. camilla.ferrario@inria.fr. · Bordeaux University Hospital (CHU), Bordeaux, France.

Preclinical

Key points

From the paper's conclusion
  • These results demonstrate the feasibility of converting non-invasive SWE measurements into model-consistent mechanical signatures and provide a basis for physics-informed myocardial phenotyping in clinical cohorts.

Abstract

Shear wave elastography (SWE) enables non-invasive acquisition of cycle-resolved myocardial stiffness dynamics, but translating the resulting stiffness waveforms into interpretable mechanical parameters remains a challenging inverse problem. In vivo SWE stiffness reflects the combined effects of passive tissue properties, active contraction, and subject-specific loading conditions, making separation of passive and active contributions essential for distinguishing alterations in myocardial material properties from changes in contractile function. We developed a computational framework based on a closed-loop reduced-order electromechanical model to address this problem. Personalisation was formulated as a sequential inverse problem. An effective passive stiffness contribution was first identified from the diastolic portion of the SWE waveform. The active parameters were then estimated from the residual full-cycle stiffness dynamics. The parameter k 0 defines the maximum active stiffness, while k ATP and k SR govern contraction and relaxation rates, respectively. Parameter estimation used a cohort-regularised objective optimized with the covariance matrix adaptation evolution strategy (CMA-ES). The framework was evaluated in 20 healthy paediatric volunteers, achieving a median active-target mean absolute error of 1.19 kPa and a median correlation of 0.995 for the retained subject-specific solutions. Repeated seeded optimisations yielded highly reproducible objective values, while k ATP showed the greatest across-seed variability, indicating lower identifiability than the other active parameters. These results demonstrate the feasibility of converting non-invasive SWE measurements into model-consistent mechanical signatures and provide a basis for physics-informed myocardial phenotyping in clinical cohorts.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

In Vivo cardiac biomechanical model parameter estimation from ultrafast shear wave elastography — Science Skim