In Vivo cardiac biomechanical model parameter estimation from ultrafast shear wave elastography.
Camilla Ferrario, Maëlys Venet, Olivier Villemain, Maxime Sermesant
Inria, Sophia Antipolis, France. camilla.ferrario@inria.fr. · Bordeaux University Hospital (CHU), Bordeaux, France.
Key points
From the paper's conclusion- These results demonstrate the feasibility of converting non-invasive SWE measurements into model-consistent mechanical signatures and provide a basis for physics-informed myocardial phenotyping in clinical cohorts.
Abstract
Shear wave elastography (SWE) enables non-invasive acquisition of cycle-resolved myocardial stiffness dynamics, but translating the resulting stiffness waveforms into interpretable mechanical parameters remains a challenging inverse problem. In vivo SWE stiffness reflects the combined effects of passive tissue properties, active contraction, and subject-specific loading conditions, making separation of passive and active contributions essential for distinguishing alterations in myocardial material properties from changes in contractile function. We developed a computational framework based on a closed-loop reduced-order electromechanical model to address this problem. Personalisation was formulated as a sequential inverse problem. An effective passive stiffness contribution was first identified from the diastolic portion of the SWE waveform. The active parameters were then estimated from the residual full-cycle stiffness dynamics. The parameter k 0 defines the maximum active stiffness, while k ATP and k SR govern contraction and relaxation rates, respectively. Parameter estimation used a cohort-regularised objective optimized with the covariance matrix adaptation evolution strategy (CMA-ES). The framework was evaluated in 20 healthy paediatric volunteers, achieving a median active-target mean absolute error of 1.19 kPa and a median correlation of 0.995 for the retained subject-specific solutions. Repeated seeded optimisations yielded highly reproducible objective values, while k ATP showed the greatest across-seed variability, indicating lower identifiability than the other active parameters. These results demonstrate the feasibility of converting non-invasive SWE measurements into model-consistent mechanical signatures and provide a basis for physics-informed myocardial phenotyping in clinical cohorts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Uncertainty Quantification in Cardiac Model Personalisation from Ultrafast UltrasoundarXiv · 2026
- Automatic Reconstruction Algorithms for In Vivo Skeletal Muscle 3D-SWEI Data.IEEE transactions on ultrasonics · 2026
- Quantitative assessment of regional myocardial stiffness and anisotropy using 3D Shear Wave ElastographyEuropean Heart Journal · 2026
- 3D ultrasound shear wave elastography quantifies myocardial stiffness and anisotropy in the human heart.Physics in medicine and biology · 2026
- Evaluating the impact of passive driver position on image consistency and repeatability in 3.0T cardiac magnetic resonance elastography.Frontiers in radiology · 2026
- Estimation of shear wave 3D velocity fields from echocardiographic time-of-flight data using physics-informed neural networks.IEEE transactions on ultrasonics · 2026