Personalized biventricular mechanics and sensitivity to model morphology.
Aaron L Brown, Lei Shi, Matteo Salvador, Fanwei Kong, Daniel B Ennis, Ian Chen, Vijay Vedula, Alison L Marsden
Department of Mechanical Engineering, Stanford University, Stanford, CA, USA. · Department of Mechanical Engineering, Kennesaw State University, Marietta, GA, USA.
Key points
From the paper's conclusion- We then use this model as a baseline to assess the impact of two commonly used anatomical simplifications: a truncated BiV (t-BiV) model cut at the basal plane and a left ventricle-only (LV) model.
Abstract
We present a computational framework for patient-specific modeling of biventricular (BiV) mechanics based on standard clinical data, including electrocardiogram (ECG), cuff blood pressure, and ECG-gated computed tomography angiography (CTA) imaging. The model is coupled to a closed-loop lumped-parameter network (LPN) circulatory model and incorporates rule-based fiber architecture, as well as spatially varying epicardial boundary conditions to approximate surrounding tissue support. Model parameters are personalized through a multistep procedure that sequentially tunes circulatory dynamics, passive mechanics, and active contraction. The resulting personalized BiV model reproduces the clinical hemodynamic targets used during calibration and demonstrates reasonable agreement with image-based myocardial deformation metrics that were not directly included in the parameter-tuning process. We then use this model as a baseline to assess the impact of two commonly used anatomical simplifications: a truncated BiV (t-BiV) model cut at the basal plane and a left ventricle-only (LV) model. With all parameters held fixed, the LV model exhibits similar global pressure/volume behavior compared to the BiV model, despite moderate differences in regional deformation. In contrast, the t-BiV model produces substantial differences from the full BiV baseline in both global function and local myocardial mechanics. While drawn from a single-patient case study, these results demonstrate that anatomical simplifications can substantially affect model outputs, motivating further investigation across larger cohorts, disease states, and model complexity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Probabilistic calibration of a closed-loop cardiac electromechanical model with application to cardiac resynchronization therapynpj Digital Medicine · 2026
- A latent ODE approach to full-cycle biventricular cardiac motion modeling from cine MRI.Medical image analysis · 2026
- Development of a Simplified Multi-Physics Computational Model of the Coronary Microcirculation.Annals of biomedical engineering · 2026
- Learning to Beat: Phenotype-Guided Latent Flow with Regional Motion Priors for Biventricular Motion SynthesisarXiv · 2026
- Semi-automated Generation and Hemodynamic Assessment of Surgical Baffle Geometry for Biventricular Repair.Annals of biomedical engineering · 2026
- Biomechanics-guided engineering of in vitro cardiac tissues for mechanical function reconstruction.Biomaterials advances · 2026