Diagnostic yield of repeat CT pulmonary angiography after a negative examination in the emergency department.
Natalia Gorelik, Tiffany Fung, Eliana Sacher, Lorenna Mendonça de Albuquerque, Joseph Najjar, Erfan Sadri, Sylvain Grange, José A Correa
Department of Diagnostic Radiology, Faculty of Medicine and Health Sciences, McGill University, 3605 de la Montagne Street, Montréal, QC, H3G 2M1, 514-934-1934, Canada. natalia.gorelik@mail.mcgill.ca. · Department of Diagnostic Radiology, Faculty of Medicine and Health Sciences, McGill University, 3605 de la Montagne Street, Montréal, QC, H3G 2M1, 514-934-1934, Canada.
Key points
From the paper's conclusion- Repeat CTPA after a negative examination demonstrated a lower diagnostic yield than initial imaging, highlighting an opportunity for more selective use of repeat CTPA guided by clinical pretest probability.
Abstract
PURPOSE: Although repeat CT pulmonary angiography (CTPA) after a negative index examination in the emergency department (ED) is common, its diagnostic utility remains uncertain. This study aimed to determine the incidence and diagnostic yield of repeat CTPA after a negative index examination in the ED. METHODS: This retrospective cohort study included adults undergoing CTPA across three EDs at our center from 2016 to 2017. CTPA results were classified as positive, negative, or other (equivocal or negative with reported limitations) based on radiology reports. Patients with a negative index CTPA were followed for two years to identify repeat examinations. Diagnostic yield of repeat CTPA at 1 month, 1 year, and 2 years was compared with that of the index examination using a likelihood ratio test for nested proportions. RESULTS: Among 3,112 patients (median age, 60.1 years; 59.1% women), 331 (10.6%) had a positive index CTPA. Of 2,412 patients with a negative index examination, 297 (12.3%) underwent repeat CTPA within 2 years, including 202 (8.4%) performed in our ED. The diagnostic yield of repeat CTPA performed in our ED was lower than that of the index examination: 3.8% (1/26; p = 0.20) at 1 month, 6.0% (9/150; p = 0.051) at 1 year, and 6.4% (13/202; p = 0.04) at 2 years. CONCLUSION: Repeat CTPA after a negative examination demonstrated a lower diagnostic yield than initial imaging, highlighting an opportunity for more selective use of repeat CTPA guided by clinical pretest probability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Decision Moments and Pulmonary Embolism Diagnostic Quality in the Emergency Department.JAMA network open · 2026
- Dual-energy computed tomography pulmonary angiography for pulmonary embolism: a three-tier evidence framework to guide individualized low-iodine scanning.Diagnostic and interventional radiology (Ankara, Turkey) · 2026
- Evaluating Age-Adjusted D-dimer and Clinical Decision-Making in Suspected Pulmonary Embolism: A Retrospective Clinical Audit and Practitioner Survey.Cureus · 2026
- Performance of pulmonary embolism diagnostic strategies in patients undergoing computed tomography pulmonary angiography.Internal and emergency medicine · 2026
- Triple-rule-out computed tomography (CT) angiography revisited: selective contemporary use enabled by sequential acquisition and modern cardiovascular computed tomography (CT).Clinical radiology · 2026
- Comparison of three diagnostic strategies for suspicion of pulmonary embolism: planar ventilation/perfusion scan, CT pulmonary angiography and single-photon emission CT ventilation/perfusion scan – a multicentre, non-inferiority randomised controlled trialEuropean Respiratory Journal · 2026