Optimizing MALDI-TOF MS for routine dermatophyte identification, including Trichophyton indotineae.
Oğuzhan Bingöl, Hazal Kandemir, Engin Kaplan, Nevzat Ünal, Ahmet Süel, Çağrı Ergin, Murat Durdu, Macit Ilkit
Division of Mycology, Department of Microbiology, Faculty of Medicine, Çukurova University, Adana, Türkiye. · Department of Environmental Biology, Institute of Environmental Sciences (CML), Leiden University, Leiden, the Netherlands.
Key points
From the paper's conclusion- These findings support the use of MALDI-TOF MS as a rapid and practical tool for routine dermatophyte identification and highlight the importance of optimized culture conditions for maximizing diagnostic performance. A simple, inexpensive change in laboratory workflow can therefore make routine identification of dermatophytes, including T. indotineae, reliable enough for everyday diagnostic use.
Abstract
BACKGROUND: Dermatophytosis is a common superficial fungal infection worldwide, and the recent global spread of the terbinafine-resistant fungus Trichophyton indotineae has made rapid, accurate species identification a priority for clinical laboratories. This study assessed the identification performance of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) using molecularly identified dermatophyte isolates recovered from chronic, recalcitrant, and widespread infections. METHODS: A total of 134 dermatophyte isolates were analyzed, including 119 Trichophyton indotineae, 10 T. rubrum, 3 T. tonsurans, and 2 Microsporum canis. Isolates were cultured on ID Fungi Plates (IDFPs), Sabouraud glucose agar (SGA), and Kimmig agar and incubated at 27 °C for 72 h. MALDI-TOF MS analysis was performed using the VITEK® MS PRIME system. Identification performance was compared across the three culture media. RESULTS: IDFP achieved the highest species-level identification rate (97.8%), followed by SGA (87.3%) and Kimmig agar (75.4%). For T. indotineae, species-level identification was also highest with IDFP (97.5%), followed by SGA (88.2%) and Kimmig agar (74.8%). CONCLUSIONS: These findings support the use of MALDI-TOF MS as a rapid and practical tool for routine dermatophyte identification and highlight the importance of optimized culture conditions for maximizing diagnostic performance. A simple, inexpensive change in laboratory workflow can therefore make routine identification of dermatophytes, including T. indotineae, reliable enough for everyday diagnostic use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Species Distribution, Species Characterization, and Antifungal Susceptibility of Clinical Dermatophyte IsolatesMantar dergisi · 2026
- Validation of the Mycelium Transfer Method Coupled with MALDI-TOF MS for Rapid Identification of Filamentous Fungi.Pathogens (Basel, Switzerland) · 2026
- Global Spread of Trichophyton indotineae Tracked by Mass Spectrometry Identification Network, 2022-2025.Emerging infectious diseases · 2026
- Consensus recommendations for Trichophyton indotineae: A modified Delphi study.Journal of the European Academy of Dermatology and Venereology : JEADV · 2026
- The emergence of superficial dermatophytosis due to Trichophyton indotineae and Trichophyton mentagrophytes genotypes VII and II* in New York: a need for comprehensive testing approachesJournal of Clinical Microbiology · 2026
- Emerging terbinafine-resistant Trichophyton indotineae between 2018 and 2023: a multinational genomic epidemiology studyThe Lancet Microbe · 2026