Perioperative management of aortic root thrombus following HeartMate 3 implantation: review of the literature.
Toshihide Izumida, Teruhiko Imamura, Makiko Nakamura, Masaki Nakagaito, Shigeki Yokoyama, Saori Nagura, Toshio Doi, Koichiro Kinugawa
Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama, 930-0194, Japan. · Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama, 930-0194, Japan. teimamu@med.u-toyama.ac.jp.
Key points
From the paper's conclusion- We report 2 cases of early, asymptomatic ART detected on postoperative day 2 by routine transthoracic echocardiography after HeartMate 3 implantation.
Abstract
Aortic root thrombosis (ART) is an increasingly recognized complication in patients supported with continuous-flow left ventricular assist devices (LVADs), although its incidence, prognosis, and optimal management remain poorly defined. We report 2 cases of early, asymptomatic ART detected on postoperative day 2 by routine transthoracic echocardiography after HeartMate 3 implantation. In both cases, ART developed in the setting of a persistently closed aortic valve and was identified before embolic complications occurred. Both patients were successfully managed with intensified anticoagulation, temporary pump speed escalation to maintain valve closure, and temporary restriction of physical activity. ART resolved completely without symptomatic embolic events, invasive intervention, or antiplatelet therapy, and no recurrence was observed during follow-up. These cases and the available literature suggest that early ART may be clinically silent and underrecognized even in the contemporary HeartMate 3 era. Routine early echocardiographic surveillance may facilitate timely detection, and a conservative, physiology-guided strategy focused on anticoagulation and flow adjustment appears effective in carefully selected patients under close monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- ST-Segment Elevation Myocardial Infarction Secondary to Aortic Root Thrombosis in a Patient With a Left Ventricular Assist Device.Cureus · 2026
- Abrupt flow decline as the initial indicator of early HeartMate 3 pump thrombosis.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2026
- Case report: aortic root thrombus presenting with syncope and embolic events.European heart journal. Case reports · 2026
- Feasibility and Midterm Outcomes of Concomitant Aortic Valve Plasty in Contemporary HeartMate 3 Practice.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026
- Delayed Embolic Stroke From Thrombus Around Microaxial Flow Pump Insertion Site in Ascending Aorta.JACC. Case reports · 2026
- Transcatheter aortic valve thrombosisEuroIntervention · 2026