Hernia : the journal of hernias and abdominal wall surgery

From inert to uncertain: Polypropylene mesh degradation and the microplastics question - a narrative review of the literature.

Salvatore Docimo, Catalina Pineda Molina, George S Hussey

Department of Surgery, Section of Abdominal Wall Surgery, University of South Florida / Tampa General Hospital, Tampa, FL, USA. sdocimo@gmail.com. · Department of Surgery, School of Medicine, McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, USA.

Review

Key points

From the paper's conclusion
  • PP mesh degradation and microplastic/nanoplastic particle generation appear biologically real and locally consequential, even as current clinical epidemiology does not support a systemic autoimmune signal. Future work should pair graded material characterization with graded clinical outcome measures and extend follow-up and comparator design toward resorbable constructs.

Abstract

PURPOSE: To review the literature on polypropylene (PP) mesh degradation following implantation for hernia repair, examine the recent reframing of degradation debris as a microplastics exposure, and compare this material-science literature against the clinical epidemiology of PP mesh and systemic autoimmune disease. METHODS: Narrative review of 46 peer-reviewed sources identified through a structured literature search (8 queries yielding 27 sources) supplemented by citation chasing during manuscript drafting and revision (19 additional sources), following a two-stage PRISMA-style identification process. RESULTS: Explant, in vitro, and mechanistic studies demonstrate that PP mesh undergoes measurable surface oxidation, cracking, and molecular weight change after implantation. Degradation debris is increasingly characterized using microplastics methodology and has been shown to activate macrophages toward a sustained pro-inflammatory, pro-fibrotic phenotype. A body of large, matched cohort studies and a pooled meta-analysis has found no significant association between PP mesh and systemic autoimmune disease. A genuine, unresolved methodological dispute persists over whether reported degradation reflects true polymer breakdown or cleaning-protocol artifact. CONCLUSION: PP mesh degradation and microplastic/nanoplastic particle generation appear biologically real and locally consequential, even as current clinical epidemiology does not support a systemic autoimmune signal. Future work should pair graded material characterization with graded clinical outcome measures and extend follow-up and comparator design toward resorbable constructs.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers