Acta Neurochirurgica

Development of a novel continuous fluid-filled cadaveric model for full endoscopic intraventricular surgical simulation: anatomic demonstration

Francesco Tengattini, Vitor De Deus da Rocha Ribeiro Gonçalves, Edoardo Agosti, Matteo De Notaris, Pier Paolo Panciani, Alessandro Fiorindi, Marco Maria Fontanella, Alberto Prats-Galino,

Computational

Key points

From the paper's conclusion
  • We developed a continuous fluid-filled body donor anatomical model to recreate a realistic intraventricular environment for anatomical research, neuroendoscopic simulation, and surgical training.

Abstract

Purpose Realistic body donor anatomical simulation of intraventricular neuroendoscopy remains limited because ventricular collapse following cerebrospinal fluid loss prevents preservation of physiological ventricular anatomy. We developed a continuous fluid-filled body donor anatomical model to recreate a realistic intraventricular environment for anatomical research, neuroendoscopic simulation, and surgical training. As a separate but complementary objective, the model was used to demonstrate the feasibility of a novel endoscope-controlled bimanual intraventricular approach transitioning from initial fluid-filled ventricular exploration to dry-field surgery. Methods Five fresh body donor anatomical heads were prepared using a gravity-driven ventricular filling system through a frontal external ventricular catheter. A fully endoscopic transcortical approach was performed using exclusive endoscopic visualization and bimanual microsurgical dissection through a mini-corticectomy. Anatomical exposure, surgical manoeuvrability, and model feasibility were qualitatively assessed. Results Continuous gravity-driven infusion consistently restored and maintained ventricular distension, preserving ventricular anatomy throughout the procedures. Successful ventricular cannulation was achieved in all five specimens, with procedural completion in three. High-quality visualization of the lateral and third ventricles enabled detailed identification of the principal intraventricular landmarks. The proposed approach allowed unrestricted bimanual instrument manipulation through a single surgical corridor under continuous endoscopic visualization and without the need for static retractors. Conclusions The proposed fluid-filled fresh body donor anatomical model provides a realistic and reproducible platform for neuroendoscopic anatomical research, surgical simulation, and training. It preserves ventricular anatomy, enables high-quality endoscopic documentation, and facilitates the evaluation of novel intraventricular techniques. Within this environment, the proposed minimally invasive endoscopic approach proved feasible and reproducible while preserving unrestricted bimanual microsurgical manipulation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers