Manganese dioxide-gold nanoparticle synergistic platform for sensitive colorimetric detection of creatinine in clinical samples.
Jalal N Jeber, Azhar Kamel, Maher Ahmed Abed, Aktham N Jasim
Department of Chemistry, College of Science, University of Baghdad, Baghdad, 10071, Iraq. jalal.n@sc.uobaghdad.edu.iq. · Ministry of Higher Education and Scientific Research, Supervision and Scientific Evaluation Apparatus, Baghdad, Iraq.
Key points
From the paper's conclusion- Requiring only 5 µL of serum, yielding results within 10 min, and costing less than $0.08 per test, this nanozyme-plasmonic architecture offers a robust, low-cost, and interference-resistant alternative to conventional creatinine assays in central and decentralised clinical laboratories.
Abstract
A dual-nanoparticle cascade platform is reported that resolves these limitations by architecturally decoupling chemical recognition from optical transduction, thereby achieving both high selectivity and intrinsic matrix tolerance in a single colorimetric format. The platform couples δ-MnO2 nanosheets, acting as a surface-selective nanozyme, with citrate-stabilised gold nanoparticles (AuNPs) as the plasmonic transducer. In the first step, creatinine undergoes a two-electron oxidation at the surface MnIV sites of δ-MnO2 nanosheets, yielding N-methylhydantoin with stoichiometric release of Mn2+ (1:1 molar ratio confirmed by LC-MS/MS and ICP-MS). The liberated Mn2+ ions subsequently displace the citrate stabilising layer of the AuNPs and compress their electrical double layer, triggering irreversible colloidal aggregation and a near-infrared shift of the localised surface plasmon resonance from 522 nm to 700 nm. This 700 nm detection window lies entirely beyond the absorption bands of the major serum chromophores, oxyhaemoglobin (415, 541, 577 nm) and bilirubin (450 nm), providing intrinsic spectral immunity to haemolytic and icteric interference without any sample pre-treatment. Under optimised conditions (MES buffer, pH 6.5; 60 °C, 10 min), the assay exhibits linearity over 26-535 µM (R2 = 0.9915), a limit of detection of 8.58 µM, and intra- and inter-assay precision of 1.9-7.4% and 2.1-8.1% RSD, respectively, with mean spike recovery of 99.4-103.6% in matrix-matched pooled human serum. The selectivity against twenty-six endogenous and exogenous interferents, including the four major serum proteins (albumin, IgG, transferrin, fibrinogen), five clinically relevant antibiotic classes (cephalosporin, penicillin, aminoglycoside, fluoroquinolone, glycopeptide), and structural analogues such as creatine, was quantified; only L-cysteine and dopamine produced deviations exceeding 10%, both of which were fully suppressed by N-ethylmaleimide pre-treatment without affecting creatinine recovery. Prospective evaluation against 120 clinical serum specimens, spanning healthy controls (n = 20), CKD stages 1-2 (n = 25), CKD stage 3 (n = 25), CKD stages 4-5 (n = 25), acute kidney injury (n = 15), and hemolytic/icteric samples (n = 10) which demonstrated excellent agreement with the enzymatic reference analyser (Pearson r = 0.997; Passing-Bablok slope = 1.024, intercept = - 3.5 µM; 94.2% of data points within Bland-Altman ± 1.96 SD limits of agreement). Subgroup-stratified recovery analysis showed no significant inter-subgroup differences (F5,114 = 0.83, p = 0.53), and CKD staging concordance with the enzymatic reference reached 100% across all 95 CKD/AKI specimens. Six independent sensor preparations synthesised on different days yielded an inter-batch calibration-slope RSD of 2.5%, with no statistically significant inter-batch differences (one-way ANOVA, F5,24 = 1.96, p = 0.12); a 180-day storage-stability study supported an in-use shelf-life of 120 days at 4 °C with full spike-recovery retention (95-105% throughout); and 50 consecutive measurements in a single working day yielded 1.7% within-run RSD with no detectable drift. Requiring only 5 µL of serum, yielding results within 10 min, and costing less than $0.08 per test, this nanozyme-plasmonic architecture offers a robust, low-cost, and interference-resistant alternative to conventional creatinine assays in central and decentralised clinical laboratories. While the present implementation requires a 60 °C heating block and a spectrophotometric reader and therefore does not yet satisfy all WHO ASSURED criteria for fully equipment-free point-of-care use, the underlying chemistry, low reagent cost and minimal sample volume make it an attractive candidate for subsequent translation to lyophilised reagent strips with smartphone-based readout.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Plasmonic property of gold nanoparticles to predict nanozyme activity: towards the colorimetric detection of manganese(ii).RSC advances · 2026
- Rapid colorimetric detection of trace-level catechol and hydroquinone using a robust, highly active δ-MnO2 nanoflower nanozyme synthesized under mild conditions.Talanta · 2026
- Au nanoparticle-loaded mixed-valence MnOₓ nanosheets as an oxidase-like nanozyme for rapid colorimetric determination of leucomalachite green in fish and water.Mikrochimica acta · 2026
- Mn-CDs@Pt nanozyme with high oxidase-like activity for smartphone-assisted colorimetric sensing of acrylamide.Food chemistry: X · 2026
- Enzyme-free voltammetric sensor for monitoring of creatinine in diabetic patient using sustainable L-cysteine/AuNPs/rGO nanocomposite.Clinica chimica acta; international journal of clinical chemistry · 2026
- Polyhedral MgMn2O4 oxide nanozyme based for visual detection of epinephrine.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026