Mikrochimica acta

A ratiometric electrochemical sensor for 17β-estradiol detection in milk based on a Cu2+-mediated imprinted polymer and aptamer cascade.

Jiatong Xin, Yingqi Wang, Xiwen Liu, Tongkai Zhang, Jinyang Yu, Xiaopeng Hu, Yiwei Liu

College of Life Science, Yangtze University, Jingzhou, 434023, Hubei Province, PR China. · College of Life Science, Yangtze University, Jingzhou, 434023, Hubei Province, PR China. tongkai-zhang@yangtzeu.edu.cn.

Key points

From the paper's conclusion
  • This intrinsic self-calibration facilitates the quantification of E2, achieving remarkable limits of detection (LODs) in phosphate-buffered saline 7.27 × 10- 2 ng·mL- 1 and of 8.78 × 10- 2 ng·mL- 1 in milk.

Abstract

Tracing 17β-estradiol (E2) in dietary sources is critical for mitigating endocrine disruption risks, yet direct electrochemical screening in protein-rich matrices like milk is typically restricted by severe non-specific background fouling. To bypass this limitation, a self-correcting ratiometric platform was engineered by coupling an aptamer-molecularly imprinted polymer (Apt-MIP) cascade with gold nanoparticle-decorated bimetallic metal-organic framework (MOF)-derived nitrogen-doped carbon (AuNPs/NC). Distinct from traditional imprinting dependent on weak non-covalent forces, Cu2+ ions were integrated into the polydopamine (PDA) matrix as dynamic coordination bridges. Density functional theory (DFT) computations validate that this Cu2+-mediation establishes robust metal-ligand bonds, thereby fundamentally amplifying the target-binding affinity and spatial selectivity of the cavities. During analysis, the electroactive PDA scaffold simultaneously provides a highly stable internal standard peak. By exploiting the target-to-reference signal ratio (IE2/IPDA), the system mathematically normalizes matrix-induced signal drifts. This intrinsic self-calibration facilitates the quantification of E2, achieving remarkable limits of detection (LODs) in phosphate-buffered saline 7.27 × 10- 2 ng·mL- 1 and of 8.78 × 10- 2 ng·mL- 1 in milk. More importantly, the platform delivers precise quantification in spiked tap water and commercial milk samples, completely avoiding complicated sample dilution protocols. By merging DFT-guided coordination chemistry with ratiometric signal correction, this design establishes a resilient analytical method for rapid food safety monitoring.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A ratiometric electrochemical sensor for 17β-estradiol detection in milk based on a Cu2+-mediated imprinted polymer and aptamer cascade — Science Skim