Mikrochimica acta

Integrated SERS immunosensing chip for ultrasensitive detection of multiple breast cancer biomarkers (CEA and HER2) in human serum.

Zeyang Liu, Chengbin Fu, Lili Wang, Zufang Huang, Ping Chen, Lingna Wang, Xueliang Lin, Shangyuan Feng

Key Laboratory of OptoElectronic Science and Technology for Medicine, Ministry of Education, Fujian Provincial Key Laboratory for Photonics Technology, Fujian Normal University, Fuzhou, 350007, China. · Department of Breast Surgery, Fujian Medical University Union Hospital, Fuzhou, 350001, China.

Key points

From the paper's conclusion
  • Spike-recovery experiments in human serum further demonstrated concentration-dependent analytical responses under the tested serum matrix conditions, while analysis of clinical serum specimens revealed significantly higher SERS responses in patient groups than in healthy controls.

Abstract

A two-dimensional surface-enhanced Raman scattering (SERS) immunosensing platform was developed that integrates Au@4-MBA@Ag core-shell immunoprobes with a Si@Ag nanochip in a double-antibody sandwich format for quantitative detection of carcinoembryonic antigen (CEA) and human epidermal growth factor receptor 2 (HER2). Paired antibodies recognized distinct epitopes of each target antigen, enabling formation of a probe-antigen-chip immunocomplex, with the characteristic Raman band of 4-mercaptobenzoic acid at 1078 cm⁻¹ serving as the analytical readout. The Au@4-MBA@Ag immunoprobes exhibited uniform morphology, favourable colloidal stability and strong Raman enhancement, whereas the densely assembled Ag nanoparticle layer on the silicon substrate provided a stable SERS-active interface for signal acquisition. The platform generated concentration-dependent responses for both biomarkers, showed minimal interference from non-target proteins and achieved estimated limits of detection of 1.10 pg mL⁻¹ for HER2 and 11.06 pg mL⁻¹ for CEA. Spike-recovery experiments in human serum further demonstrated concentration-dependent analytical responses under the tested serum matrix conditions, while analysis of clinical serum specimens revealed significantly higher SERS responses in patient groups than in healthy controls. Owing to its low sample consumption, relatively simple workflow and rapid analytical readout, the platform may provide a basis for adjunctive serological assessment, longitudinal biomarker monitoring and future integration with portable Raman instrumentation for point-of-care testing.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers