Mikrochimica acta

Machine learning-assisted Ce/Co metal-organic framework-based fluorescence/electrochemical dual-modal sensor for sensitive detection of ochratoxin A.

Muhammad Mujeeb Ashraf, Kashif Chaudhary, Ahmad Junaid Ashraf, Akhtar Hayat, Saima Zulfiqar, Shahid Ali, Safyan Akram Khan, Muhammad Mansha,

Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University, Lahore Campus, Islamabad, Lahore, 54000, Pakistan. · Department of Physics, University of the Punjab, Quaid Azam Campus, Lahore, Pakistan.

Computational

Key points

From the paper's conclusion
  • The proposed approach combines bioreceptor-free operation, dual-mode verification, machine learning-assisted analysis, and highly sensitive detection capability, providing clear advantages in sensitivity and analytical reliability, supporting Sustainable Development Goal 3 (Good Health and Well-Being).

Abstract

Ochratoxin A (OTA) is a highly toxic mycotoxin that poses serious risks to food safety and human health. Herein, a rationally designed cerium-cobalt metal-organic framework (Ce/Co-PTC-MOF) was developed as a dual-mode opto-electrochemical sensing platform for rapid, selective, and bioreceptor-free detection of OTA. The flower-like Ce/Co-PTC-MOF efficiently quenches rhodamine B (Rh-B) fluorescence through electrostatic interactions, while the redox-active Ce/Co centers enabled direct OTA recognition without biological receptors. OTA binding alters the MOF environment, weakening dye-MOF quenching and enabling concentration-dependent fluorescence recovery for sensitive detection. Machine-learning (ML) regression models were integrated with fluorescence data to improve quantitative prediction and analytical reliability. Under optimized conditions, the fluorescence sensor exhibited a linear detection range of 3-220 pg/mL, with a calculated limit of detection (LOD) of 0.0616 pg/mL based on the 3σ/S method. The electrochemical sensing mechanism was primarily evaluated using electrochemical impedance spectroscopy (EIS), where OTA induced interfacial blocking and produced a quantitative increase in charge-transfer resistance (Rct). Differential pulse voltammetry (DPV) was further employed as an independent electrochemical validation approach. Real sample analysis demonstrated satisfactory recoveries of and for the fluorescent and electrochemical modes, respectively with results validated against HPLC. The proposed approach combines bioreceptor-free operation, dual-mode verification, machine learning-assisted analysis, and highly sensitive detection capability, providing clear advantages in sensitivity and analytical reliability, supporting Sustainable Development Goal 3 (Good Health and Well-Being).

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers