A hemicyanine-based activatable near-infrared probe for cysteine and its fluorescence response in a mouse model of polycystic ovary syndrome.
Wei-Bo Zhao, Zhi-Bing Wu, Rong Zhao, Li-Yun Mao, Li-Jing Liu, Han Liu, Ya-Hong Zhou, Cheng Zeng
Department of Gynecology, The First Affiliated Hospital of Guangzhou, University of Chinese Medicine, Guangzhou, Guangdong, 510405, China. · Department of Gynaecology and Obstetrics, Shuyang Affiliated Hospital of Nanjing University of Traditional Chinese Medicine, Suqian, 223600, China.
Key points
From the paper's conclusion- These results support exploratory fluorescence measurements with HD-ZWB in PCOS-related models.
Abstract
Altered sulfur amino acid metabolism motivates the investigation of cysteine (Cys)-responsive fluorescence in polycystic ovary syndrome (PCOS)-related models. We developed HD-ZWB, an acrylate-caged hemicyanine probe that exhibits near-infrared fluorescence enhancement upon exposure to Cys. The response is consistent with a proposed Michael addition-cyclization pathway that releases the hemicyanine fluorophore. Under the specified buffer conditions, emission at 740 nm increased linearly over 1-10 µM Cys, with a reported detection limit of 0.01 µM, and approached a plateau within approximately 60 min. Preferential fluorescence activation by Cys was observed relative to the tested interferents. Cell viability remained above 80% at probe concentrations up to 50 µM. In OVCAR3 cells, the activated fluorescence overlapped with a mitochondrial marker and showed treatment-dependent endpoint differences following exposure to PMA, SIN-1, LPS, or N-acetylcysteine. Curcumin also reduced the endpoint signal in a high-content screen. In the PCOS mouse model, fluorescence was detectable at 15 min and peaked near 30 min; probe-treated PCOS serum showed approximately five-fold higher fluorescence than control serum. These results support exploratory fluorescence measurements with HD-ZWB in PCOS-related models. Independent Cys quantification and further chemical validation are required to assign the biological signals quantitatively to Cys, and the present data do not establish reversible sensing or diagnostic performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Cys-responsive fluorescent sensor for monitoring Cys levels in a polycystic ovary syndrome mouse model.The Analyst · 2026
- An ESIPT-ICT synergistic near-infrared probe for selective detection of Cys in HeLa cells and zebrafish.Bioorganic chemistry · 2026
- A Red-Emissive TCF-Based Fluorescent Probe for Selective Cysteine Detection in Food Samples and Living Cells.Journal of fluorescence · 2026
- Development of a Fluorescent Probe for Real-Time In Vivo Imaging of Cysteine Dynamics in a Mouse Model of Lipopolysaccharide-Induced Acute Lung Injury.Bioconjugate chemistry · 2026
- A versatile dicyanovinyl-based fluorescent probe for selective monitoring of cysteine in germinating seeds and living systems.The Analyst · 2026
- An activatable hemicyanine probe for fluorescence imaging in experimental sepsis and acute lung injury.Biosensors & bioelectronics · 2026