MXene-polydopamine-cyanobacteria photobioelectrochemical biosensor for atrazine detection in environmental waters.
Caio César Gonçalves Silva, Maiza de Lima Bueno, Max Fabricio Falone, Lucas Felipe de Lima, William Reis de Araujo, Maria Valnice Boldrin Zanoni, Maisa Azevedo Beluomini
Instituto de Química, Universidade Estadual Paulista (UNESP), Araraquara, São Paulo, Brasil. ccg.silva@unesp.br. · Faculdade de Ciências Agrárias e Veterinárias, Universidade Estadual Paulista (UNESP), Jaboticabal, São Paulo, Brasil.
Key points
From the paper's conclusion- The biosensor was successfully applied to determine ATZ in groundwater, river water, and seawater, delivering accurate recoveries (99.75-103.9%) and offering a green alternative for on-site environmental monitoring.
Abstract
A cyanobacteria-based photobioelectrochemical biosensor was developed for the first time using Synechococcus elongatus whole cells immobilized on a Ti₃C₂Tₓ MXene electrode modified with an electropolymerized polydopamine (PDA) layer. This surface created a biotic-abiotic interface that facilitated light-driven electron transfer for the sensitive screening of photosystem II (PSII)-inhibiting herbicides in environmental waters, using atrazine (ATZ) as a model analyte. The biosensor was characterized by scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), X-ray photoelectron spectroscopy (XPS), and Fourier-transform infrared spectroscopy (FTIR). The detection strategy relies on the inhibition of PSII photosynthetic activity, which produces a concentration-dependent decrease in photocurrent. Under optimized conditions, the biosensor achieved a limit of detection (LOD) of 1.92 nM (0.414 ppb), a linear range of 5-200 nM, and a sensitivity of 177.71 nA decade⁻¹ cm⁻². Interference studies demonstrated class selectivity toward PSII-inhibiting herbicides (e.g., DCMU, simazine, desethylatrazine), with negligible response (< 10%) from non-PSII pesticides and common inorganic ions. Regarding operational stability, the device retained > 95% for 1 day and approximately 93% at day 2. However, a 61% signal loss was observed by day 5 (stored at 4 °C), highlighting an operational limitation inherent to whole-cell biological systems. The biosensor was successfully applied to determine ATZ in groundwater, river water, and seawater, delivering accurate recoveries (99.75-103.9%) and offering a green alternative for on-site environmental monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dual-response whole-cell microalgae biosensor based on ALP-associated electrochemical sensing of heavy metal cations in freshwater.Bioelectrochemistry (Amsterdam, Netherlands) · 2026
- Extracellular manganese as a redox mediator and matrix binder in cyanobacterial photoelectrochemistry.Bioelectrochemistry (Amsterdam, Netherlands) · 2026
- Engineering a Single-Plasmid Dual-Pigment Escherichia coli Biosensor for Simultaneous Colorimetric Detection of Pb(II) and Hg(II).ACS omega · 2026
- The Confinement of Multiple Interfaces for Self‐Enhanced Photoelectrochemical and Electrochemiluminescence Dual‐Mode BiosensorSmall · 2026
- Portable bioactive capsule-integrated electrochemical-colorimetric dual-mode biosensor based on Mn/Ce MOF nanozyme for rapid detection of malathion in water.Mikrochimica acta · 2026
- Indigoidine and deoxyviolacein co-pigmentation in a single bacterial cell enables visual discrimination of Pb(ii) and Hg(ii) in environmental water matrices.RSC advances · 2026